Connecting the devices, Accessing the sdhc card – Interlogix TruVision IP Open Standards Box Quick Start User Manual
Page 9

Quick Start Guide
7 EN
Connecting the devices
See Figure
(Connections on the base of the camera).
1. Ethernet RJ45 PoE port
Connect to network devices.
2. Video
output
Connect to a CCTV monitor.
3. Audio
output
Connect to an audio output.
Line level, 600 Ω.
4. Audio
input
Connect to an audio input.
2.0 to 2.4 Vp-p, 1 kΩ.
5. Power
LED
Illuminated when power is connected.
6. Power
supply
Connect +12 VDC power supply.
7. RS-485
D+,
D-
Connect to an RS-485 device such as a PTZ dome camera.
8. Alarm outputs
Connect 1A/1B and 2A/2B to alarm output devices.
9. Alarm
inputs
Connect IN1/GND and IN2/GND to alarm input devices.
10. Ground
Connect to ground.
Accessing the SDHC card
Insert an SDHC card up to 32GB for local storage in the camera (see
Figure
, item
). The card is not supplied with the camera.
Video and log files stored on the SDHC card can only be accessed via
the Web browser. You cannot access the card using TruVision
Navigator or a recording device.