Testing, Adjusting display, To adjust display brightness – Interlogix SuperBus 2000 2X16 User Manual

Page 3: To adjust display contrast

Advertising
background image

system programming to the Programming Touchpad Header
on the panel.

To do this you must first connect a Programming Touchpad
Cable (60-791) to the touchpad wires (see Programming
Touchpad Cable Installation Instructions—466-1604
, included
with the cable). Then, use the appropriate procedure for
connecting the touchpad.

To connect a programming touchpad to a Concord
Express or Concord panel with software version 2.0 or
later:

1. With the panel powered up, connect the cable to the

Programming Touchpad Header (see Figure 5 below).

Figure 5: Connecting a programming touchpad

Programming
Touchpad
Cable (60-791)

2. Activate the service touchpad by pressing 8 + CODE + 0 +

2.

3. Enter program mode by pressing 8 + installer/dealer

CODE + 0 + 0 and program the panel using the panel
documentation.

4. When programming is completed, simply disconnect the

programming touchpad.

To connect a programming touchpad to a Concord panel
with software versions 1.0–1.6:

1. Disconnect AC and backup battery power.

2. Connect the cable plug to the panel Programming

Touchpad Header pins (see Figure 5 above).

3. Reconnect the AC and backup battery power. The

touchpad briefly displays ***********,
SCANNING BUS DEVICES, then shows a time and date
display.

Note: If the touchpad does not respond as described in step 3,
there may be a bus conflict. To correct this, change the
touchpad unit number as described in the section “Changing
the Touchpad Unit Number.”

Removing the programming touchpad from Concord
panels with software versions 1.0–1.6:

To prevent a trouble condition, you must delete the
programming touchpad unit number from Concord panel
memory before disconnecting it.

1. After programming is completed, return to the

ACCESSORY MODULES menu, then press É. The
display should read BUS DEVICES.

2. Press É. The display shows the lowest unit number and its

device name.

3. Press A or B until the display shows the programming

touchpad unit number.

4. Press D to delete the device and its unit number from

panel memory. The display shows:
UNIT - TYPE
14-NONE

5. Exit program mode and disconnect the programming cable

from the panel header.

Testing

Caution:

Contact the Central Monitoring Station before

activating any alarms, to avoid dispatching local police and fire
departments.

Test the touchpad by arming/disarming the system, activating
the touchpad panics, bypassing sensors, and by turning chime
and lights on/off to verify correct operation. Refer to the panel
documentation for system operating instructions.

Adjusting Display

The touchpad display can be adjusted for easier viewing to
help compensate for lighting conditions in the touchpad
location. The brightness adjustment lightens or darkens the
background. The contrast adjustment lightens or darkens the
text.

To adjust display brightness:

1. Enter user programming mode by pressing 9 + user,

partition, or system master CODE. The display shows
SYSTEM MENU, then TIME AND DATE
(Concord panels with software versions 1.0–1.6 display
USER CODES.)

2. Press B until the display shows OPTIONS, then press É.

The display shows DOWNLOADING ON/OFF (current
setting)
.

3. Press B until the display shows TOUCHPAD

BRIGHTNESS 2 (default setting).

4. Enter a setting from 0 (darkest background) to 3 (brightest

background), then press É.

5. The display flashes the entered selection, then stops after

pressing É and displays the new setting and brightness
level.

6. Exit user programming mode by entering:


З + 0 + 0 + Й for Concord panels with software
versions 2.0 or later
or
З + 7 + Й for Concord panels with software versions 1.0–
1.6.

To adjust display contrast:

1. Enter configuration mode by pressing the D and 6 buttons

together for at least two seconds. The display shows DA
nnn
.

SuperBus 2000 2X16 LCD Alphanumeric Touchpad Installation Instructions

3