Fireplace facts, Perfectview 39ldvr, Fireplace & venting specifications – Vermont Casting 39LDVR User Manual

Page 2: Contemporary terminations, Elbows, Flue system, Product listing, Wall framing dimensions, Vent opening for combustible wall

Advertising
background image

FIREPLACE & VENTING SPECIFICATIONS

PERFECTVIEW 39LDVR REAR VENT

VENT SECTIONS

NOTE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS 1

1/2

” LESS THAN ITS TOTAL

LENGTH, EXCEPT FOR THE LAST SECTION INSTALLED.

12"

305mm

24"

610mm

36"

914mm

48"

1219mm

7TDVP8

7TDVP12

7TDVP24

7TDVP36

7TDVP48

7TDVP1218

7TDVP3564

8"

203mm

7"

178mm

35"

889mm

64"

1626mm

12"

305mm

18"

457mm

9

1/4

"

7

1/4

"

9

1/4

"

90

°

7"

13"

9

1/4

"

90

°

13"

7

1/4

"

13"

17"

OFFSET

235mm

235mm

178mm

184mm

330mm

330mm

335mm

330mm

184mm

OFFSET w/2-90

°

Back to Back

FIREPLACE FACTS

Minimum Mantel Clearances

Mantel Depth

2”

4”

6”

8”

10”

Clearance From Top

of Combustion Chamber Opening

To Bottom of Mantel

9”

11”

13”

15”

17”

CONTEMPORARY TERMINATIONS

7TDV45

7TDVRT90

11"

7

3/8

"

45

°

45

°

7

3/8

"

OFFSET w/2-45

°

Back to Back

45

°

7

3/8

"

188mm

188mm

188mm

FP890

FP889

ELBOWS

7TDVRVT

7TRVT

9³⁄₄

"

12¹³⁄₁₆"

7"

7TDVSKV

9¹⁄₂

"

7"

13³⁄₁₆"

7TDVSKS

32"

6

1/2

"

813mm

127mm

19"

16"

482mm

406mm

165

mm

5"

FEATURES:

• 39” PerfectView Direct Vent Gas Appliance
• 16,000 to 23,000 BTU/hr. input
• Patented Insta-Flame TM Ceramic Burner System with 4-piece
Split Oak Ceramic Fiber Log Set
• Tempered Glass Panel Assembly
• Adjustable Flame and Heat Output
• Wall Switch
• 18” Flex Connector with Shutoff and EB1 electrical box installed
• Wall Firestop, Zero Clearance Sleeve (Rear vent models only)
• Rated as Fireplace Heater (AFUE)
• Uses 4”/7” Majestic (Direct Vent) Venting Components

BURNER SYSTEM:

• Capacity

– Natural:

23,000 BTU/HR Max.

16,100 BTU/HR Min.

– Propane:

22,500 BTU/HR Max.

16,875 BTU/HR Min.

• Fuel - Natural or Propane Gas
• Ignition System - Standing Pilot With Piezo Ignitor, A Low
Voltage, Self-Generate Power Pile System (mV)

– No Outside Electrical Power Needed OR

– Electronic ignition that requires 120 VAC

Electrical hook up.

• Gas Supply Line -

Consult Gas Code Book for Correct Sizing

• Gas Inlet and Manifold Pressures

Natural

Propane

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

MINIMUM FLOOR AREA:

• 39” W X 16” D

HEARTH EXTENSION:

A Hearth Extension Is Recommended But

Not Required

ACCESSORIES:

39LDVCR

- 39” LDV Ceramic Refractory

FK12

- Fan and Cord (160cfm) (for RN/RP only)

FK24

- Variable Speed Heat-Activated Fan Kit

IMTFK

- IMT Thermostat w/ Face Plate

PerfectView 39LDVR

39LDVR

FLUE SYSTEM

7” Coaxial Direct Vent System

SPECIFICATIONS:

• 7” O.D.

• 4” I.D.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL

a) Rear Wall Vent Applications 2” top, 1” Sides & Bottom

b) Vertical Side Wall Applications 1” to All Sides

c) Vertical thru the Roof Applications 1” to All Sides

MINIMUM COMBUSTIBLE WALL/FLOOR OPENINGS

a) 9 3/8” x 10 3/8” H for Rear Wall Vent Applications

b) 9 3/8” W x 9 3/8” H for Vertical Side Wall/Vertical Ap-

plications

MAXIMUM INSTALLATION LENGTHS

a) Rear Wall Vent Applications

20” (508mm) Vent Length

20” (508mm) Vent Length with one 45° elbow

b) Vertical Side Wall Applications

20’ (6 m) Horizontal Vent Length with

7.5’ (2.29 m) vertical rise

*Refer to manual for alternative venting distance

VERTICAL THRU THE ROOF APPLICATIONS

8’ (2.4 m) Minimum Vertical Rise

40’ (12 m) Maximum Vertical Rise

2 sets of 45° Elbows can be used in Vertical rise

with 8’ maximum distance between elbows

Two 90° elbows maximum for 10’ (3 m)

Horizontal can be installed in Vertical

Applications

*Maximum angular variation for Vertical Sidewall/Vertical

Application in system is total of 270°

*Refer to installation manual for all venting restrictions

with elbow use

TERMINATION CLEARANCES MINIMUM

a) Horizontal

12” (305 mm) above Grade Level

18” (458 mm) to Ventilated Soffi t

12” (305 mm) to Unventilated Soffi t

12” (305 mm) under veranda, porch, deck or balcony

b) Vertical

24” (610 mm) Above a Roof Surface and any other

obstruction within a horizontal distance

of 18” (458 mm)

*Refer to installation manual for more termination

restrictions and clearance information

39LDVR ANSI Z21.88 - 2005/CSA 2.33 2005
Vented Gas Fireplace Heaters

This gas appliance should be installed by qualifi ed
installers in accordance with local building codes
and the current National Fuel Gas code ANSI Z223.1
or CSA B 149.1 Installation code for Gas Burning
Appliance and Equipment.

PRODUCT LISTING

1118mm

686mm

419mm

406mm

889mm

870mm

1581mm

790mm

1118mm

172mm

235mm

991mm

1003mm

946mm

584mm

27

3/4

708mm

83mm

476mm

302mm

203mm

143mm

24

1/4

616mm

51mm

51mm

REV. 10/07

The Fireplace Facts Information Sheets are for
quick reference only and are subject to change with-
out notice. Actual fi replace instructions must abide
by specifi cations provided with each product.

ACCESSORIES (Continued):
(continued from second page)

WALL FRAMING DIMENSIONS

Vent Opening for
Combustible Wall

• Louver Kits - Additional Louver Kits ( To replace all louvers in
desired color, 4 sets are required ) See Price List

• Filligree Louver Kits - See Price List

• Perimeter Trim Kits - See Price List

• Face Trim Kits - See Price List

NEW - Bulk Flex Kits - see Price List

Framing Detail

9 ³⁄₈"

(240 mm)

10 ³⁄₈"

(264 mm)

VO584-100

Fireplace Hearth

Rnd.

7¹⁄₂" Dia.

(190 mm)

Opening for Non-combustible Wall

Advertising