Save these instructions, Important – Intex 633T Krystal Clear 2014 User Manual

Page 12

Advertising
background image

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013

109

SAVE THESE INSTRUCTIONS

English

Page 12

CLEANING OR REPLACING FILTER CARTRIDGES (continued)

LONG TERM STORAGE

1. Before emptying your pool for long term storage, or relocation, be sure the water is

directed towards an acceptable drain water receptacle away from the house. Check local

regulations for specific directions regarding disposal of swimming pool water.

2. Disconnect power cord from electrical outlet.
3. Now, drain the pool.
4. When the pool is empty, disconnect all hoses from pump and plunger valves and remove

the strainers from the pool wall.

5. Drain all water from the filter pump.
6. Leave filter pump pieces & hoses outside to thoroughly air dry.
7. Remove both plunger valves from the threaded strainer connector (14). Be careful not to lose

the step rubber washer (11).

8. Coat the following O-rings and washers with petroleum jelly for long term storage:

• Air release valve & sediment O-rings (3).

• Filter housing cover O-ring (5).

• Pump hose O-rings (10).

• Strainer valve assembly step washers (11).

• Flat strainer rubber washers (13).

9. Discard the used filter cartridge. Put aside 1 or 2 new cartridges for next season’s use.
10. It is best to place all dry pieces in the original packaging for storage or placethem in an

airtight plastic bag.

11. Store the unit and accessories in a dry place. The storage's temperature should be

controlled, between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees

Fahrenheit (40 degrees Celsius) storage location.

7. Examine the inside of the filter housing.
8. If dirt or sediment is located on the bottom of the housing then:

A. In a counter-clockwise motion gently unscrew and remove the sediment valve (2)

located at the bottom of the housing. Place it in a safe place.

B. With a bucket of water or a garden hose pour water into the housing flushing out the

sediment.

C. Screw back the sediment valve (2) in a gentle clockwise motion. Do not over-tighten.

9. Place a new cartridge filter in the housing.
10. Return the housing cover (4) to its position and in a clockwise direction rescrew the housing
collar

(1) onto the filter housing.

11. Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valve,

allowing water to flow into the filter pump.

12. When the trapped air has escaped through the air release valve gently retighten the valve (2)

in a clockwise direction.

13. Reconnect the power cord.
14. Turn on the pump.

IMPORTANT

It is best to store away your poolsystem in its original packaging.

Advertising