Save these instructions, Important, Maintenance – Intex CS8110 User Manual

Page 20

Advertising
background image

(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013

131

SAVE THESE INSTRUCTIONS

English

Page 20

MAINTENANCE

IMPORTANT

Unplug the power cord before cleaning your system. Also close the plunger
valves on your pool or insert the black hat-like plugs in the strainer opening to
prevent water spillage. After completing all maintenance tasks, you must plug the
power cord back in and open the plunger valves or remove the plugs.

Flow Sensor Cleaning

1. In a counter-clockwise motion unscrew the collar of the flow sensor (7) and remove it from

the electrolytic cell conduit. See “Part Reference”.

2. If deposits and debris are seen on the surface of the flow sensor, then use a garden hose

to wash it off.

3. If flushing with water does not remove the deposits, use a plastic brush to clean the

surface and the hinge if necessary. Do not use a metal brush.

4. After the flow sensor has been inspected and cleaned, align the locator notch on the flow

sensor to the connection ridge in the conduit. Now turn the collar in a clockwise motion,

tightening the sensor back into its position. Do not overtighten.

Electrolytic Cell Cleaning

The electrolytic cell (4) has a self cleaning function incorporated into the electronic control's
programming. In most cases this self cleaning action will keep the cell working at optimum
efficiency. If the pool water is hard (high mineral content) the cell may require periodic manual
cleaning. To maintain maximum performance, we recommend that you open and visually
inspect the electrolytic cell (4) monthly.
The following steps provide instructions on how to clean your cell.

Inspection and cleaning:

1. Switch off the unit, unplug the power cord from the electrical socket.
2. For filter pumps with 1-1/4” (32mm) hose size - To prevent water from flowing out of the

pool, unscrew the strainer grids from the strainer connectors and insert the hat-like plugs

into the strainer connectors.

For filter pumps with 1-1/2” (38mm) hose size - Turn both plunger valve handles fully

clockwise until they stop. This closes the valve, prevents the water from flowing out of the

pool.

Connection Ridge

Locator Notch

Hinge

Advertising