INSTALLING

Continued

CONNECTING TO GAS SUPPLY

NOTICE

A qualified service person must connect heater to gas supply.
Follow all local codes.

WARNING ICON

G 001

CAUTION

Never connect heater directly to the propane supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

• external regulator (supplied by

installer, see page 16)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *

• test gauge connection *
• sediment trap
• tee joint
• pipe wrench

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 33.

Continued

Masonry Screw

Mounting
Bracket

Figure 12 - Attaching Base Assembly to Fireplace Floor