Operating heater, Caution, Thermostatically- controlled model – Desa Tech CGD3924P User Manual

Page 23: Continued

Advertising
background image

23

102991

Figure 23 - Control Knob and Ignitor Button Location

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the

floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.

5. Turn control knob counterclockwise

C-clockwise

to the PILOT position. Press in

control knob for five (5) seconds (see above).

Note:

You may be running this heater for the first time after hooking up to gas

supply. If so, the control knob may need to be pressed in for 30 seconds or less.
This will allow air to bleed from the gas system.

• If control knob does not pop out when released, contact a qualified service

person or gas supplier for repairs.

6. With control knob pressed in, press and release ignitor button. This will light

pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service person or gas supplier

for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure
on page 24.

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

release control knob.

Note:

If pilot goes out, repeat steps 3 through 7. This heater has a safety

interlock system. Wait one (1) minute for system to reset before lighting pilot
again.

OPERATING

HEATER

Thermostatically-

Controlled Model

Continued

Continued

1. STOP! Read the safety information above.

2. Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise

Clockwise

to the OFF position.

Thermocouple

Figure 24 - Pilot

Ignitor Electrode

Pilot Burner

8. Turn control knob counterclockwise

C-clockwise

to desired heating level. The

burners should light. Set control knob to any heat level between HI and LO.

WARNING ICON

G 001

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

LO

HI

OFF

Pilo

t

Control Knob

Ignitor Button

Advertising