Coleman Echelon FC9V User Manual

Page 2

Advertising
background image

246786-CTG-B-0407

2

Unitary Products Group

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
* Wire size and overcurrent protection must comply with the National Electric Code.

NOTES:

1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.

C

19-1/4

1-1/4

1-1/4

5/8

5/8

23-5/8

D

2-1/4

23-1/4

20

B

BOTTOM IMAGE

SUPPLY END

TOP IMAGE

RETURN END

LEFT SIDE

RIGHT SIDE

22-3/4

7/8

7/8

13-7/8

HORIZONTAL CONDENSATE
DRAIN OPENING 2”

JUNCTION BOX
HOLE 7/8”

GAS PIPE ENTRY 1-1/2”

CONDENSATE DRAIN
HOLE 7/8”

SIDE PIPING HOLE 3-3/8”

T-STAT WIRING 7/8” K.O.

HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4”

22-1/4

25-3/8

26-1/2

27-1/8

29

22-3/4

21-5/8

18-1/2

11-3/4

7-1/2

2-1/4

T-STAT WIRING 7/8” K.O.

HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4”

HORIZONTAL
CONDENSATE
DRAIN OPENING 1-3/4”

JUNCTION BOX
HOLE 7/8”

GAS PIPE
ENTRY 1-1/2”

CONDENSATE DRAIN
HOLE 7/8”

29

22-3/4

21-1/4

18-1/2

9-1/8

8-1/2

30-1/8

23-11/16

E

FRONT

A

40

DIMENSIONS

Models

Nominal

CFM

Cabinet

Size

Cabinet Dimension

A (in.)

B (in.)

C (in.)

D (in.)

E (IN.)

FC9V060B12DH11

1200

B

17-1/2

16-1/4

15

1-3/4

2-3/8

FC9V080B12DH11

1200

B

17-1/2

16-1/4

15

1-3/4

2-3/8

FC9V080C16DH11

1600

C

21

19-3/4

18-1/2

2-1/8

2-3/4

FC9V100C20DH11

2000

C

21

19-3/4

18-1/2

2-1/8

2-3/4

FC9V120D20DH11

2000

D

24-1/2

23-1/4

22

2-1/2

3

ELECTRICAL AND PERFORMANCE DATA

Models

Input

(High/Low)

Output

(High/Low)

Nominal

Airflow

Cabinet

Width

Total Unit

AFUE

Air Temp.

Rise

MBH

MBH

CFM

In.

Amps

%

°F

FC9V060B12DH11

60 / 39

56 / 36

1200

17-1/2

9

92

35 - 65

FC9V080B12DH11

80 / 52

75 / 49

1200

17-1/2

9

92

35 - 65

FC9V080C16DH11

80 / 52

75 / 49

1600

21

12

92

35 - 65

FC9V100C20DH11

100 / 65

93 / 61

2000

21

14

92

35 - 65

FC9V120D20DH11

120 / 78

112 / 74

2000

24-1/2

14

92

35 - 65

Models

Input

(High/Low)

Max. Outlet

Air Temp.

Blower

Blower

Size

Max.

Over-current

Protect

Min. Wire Size *

(awg) @ 75 ft.

One Way

Operating

Weight

MBH

°F

HP

Amps

In.

Lbs.

FC9V060B12DH11

60 / 39

165

1/2

7.0

11 x 8

20

14

136

FC9V080B12DH11

80 / 52

165

1/2

7.0

11 x 8

20

14

143

FC9V080C16DH11

80 / 52

165

3/4

10.2

11 x 10

20

14

159

FC9V100C20DH11

100 / 65

165

1

12.7

11 x 11

20

12

164

FC9V120D20DH11

120 / 78

165

1

12.7

11 x 11

20

12

182