Maintenance – Vermont Casting UC181N User Manual

Page 11

Advertising
background image

11

3311243

Oxygen Depletion System

For your safety, this appliance is equipped with an
oxygen depletion system. This system senses the
oxygen in the firebox and switches off the gas supply
before the amount of oxygen falls below safe levels.
(Fig. 12)

Pilot ODS Sensor

Flame

Thermocouple

Piezo Ignitor

FP1505

Fig. 12 Pilot.

Maintenance

To clean the burner and pilot assembly:

Shut off the gas supply.

Allow the unit to cool to room temperature.

Remove all the logs and brush (or vacuum) lightly.

Brush any dust buildup on the pilot assembly.

NOTE: All installation, repairs and maintenance
should be done by a qualified service person. The
appliance should be inspected before use and at
least annually by a professional service person.
More frequent cleaning may be necessary as you
detect dust or carpet lint on the appliance. It is
imperative that burners, controls, the control
compartment and air circulating passageways be
kept clean and unobstructed.

The warranty may be void and CFM Home Products
disclaims any liability for property damage or personal
injury caused as a result of the following:

1. Installation other than that required by local codes.

2. Installation of a modified (or damaged) gas log set.

3. Installation or use of a component part or accessory

not manufactured or approved by CFM Home
Products.

4. Failure to address the following:

Not for use with unprocessed (private well) gas.

Advertising
This manual is related to the following products: