Service instructions – Vermont Casting ACSM User Manual

Page 6

Advertising
background image

6

The Vermont Castings Majestic Products Company

Figure 1: Side view of the firepla
showing the firebox mounting br

Mounting
Brackets
(2 per side)

FIREBOX REMOVAL

GLASS INFORMATION

WARNING: Disconnect power before
attempting any maintenance or cleaning
to reduce the risk of fire, electrical
shock or personal injury

1.

Unplug the electrical supply to the unit.

2.

Let the fireplace cool if it has been operating.

3.

Move the fireplace away from wall to gain access
to the rear of the unit.

4.

Locate the firebox mounting brackets on the side of
the firebox. Remove the screws securing the firebox
to the mounting brackets. (Figure 1).

5.

Remove firebox by sliding it rearward out of
the casing.

6.

Gently place firebox on its back on the floor.

7.

To reinstall firebox, follow the above procedure
in reverse.

1.

Under no circumstances should this product be
operated with missing or broken glass.

2.

Do not strike or slam the glass.

3.

Do not use abrasive cleaners to clean the glass.

4.

This product uses tempered glass. Replacement
glass (with gasket) is available from the
manufacturer and replacement should be carried
out by a qualified service person.

REPLACING LIGHT BULBS

This fireplace uses two clear 120 Volt, 60 Watt, E-12
socket base light bulbs (small base, chandelier candle
type). The 60 Watt bulbs are located under the log set/
ember bed. For convenience, if one of the bulbs burns
out, it may be a good idea to replace both of the light
bulbs.
1.

Turn off power to the unit by unplugging the
power cord.

2.

Let fireplace cool if it has if it has been operating.

3.

Remove firebox from casing. (See Firebox removal)

4.

Remove the two screws securing the ember bed
and log set in position. One screw is located on
either side of the ember bed near the front.

5.

Examine the bulbs to determine which bulbs need
to be replaced.

6.

While holding the socket, unscrew defective bulb(s).

7.

Install the new light bulb(s) by screwing in while
holding the socket.

8.

Reinstall ember bed and log set.

9.

Reinstall firebox.

WARNING: Do not exceed 60 watts per
bulb for lights beneath the ember bed.
Use of higher rated bulbs may result in a
fire, causing property damage or
personal injury.

MAINTENANCE OF MOTORS

The motors used on the fan and the flame generator
assembly are prelubricated for extended bearing life and
require no further lubrication. However, periodic cleaning/
vacuuming of the fan/heater unit is recommended.

WARNING: Make sure that the power is
turned off before proceeding.

SERVICE INSTRUCTIONS