CONNECTION TO THE GAS SUPPLY

✓

Be careful when flexible pipes are used that they do not come into contact with
moving parts.

✓

To maintain the thickness of 3 cm, the hob is fitted with a channel to contain the
connection pipe.

✓

The gas inlet union can be turned in the direction required after the elbow fitting
“C” and nut “A” connection (figure 23) has been slackened (Fig. 24).

✓

Never put it in the horizontal or vertical position.

✓

Never attempt to turn the elbow “C” without having first slackened off the relative
lock

nut

“A”.

✓

The gasket “F” (fig. 23) guarantees the seal of the gas connection.

It is recommended that it be replaced whenever it shows even the slightest
deformation or imperfection.

✓

Using a suitable leak detection fluid solution (e.g. Rocol) check each gas
connection one at a time by brushing the solution over the connection.
The presence of bubbles will indicate a leak. If there is a leak, tighten
the fitting and then recheck for leaks.

IMPORTANT! Do not use a naked flame to test for leaks

Figure 24

Figure 23

1/2" G conical
(ISO 7-1) male

1/2" G cylindrical
(ISO 228-1) male

1/2" G cylindrical
(ISO 228-1) female

C

F

A

GAS CONNECTOR

Cat: II 2H3+

The fitting (fig. 23) is made up of:

✓

1 nut “A”

✓

1 elbow fitting “C”

✓

gasket “F”

GB