HP C240 User Manual

Page 175

Advertising
background image

157

SCSI Connections

SCSI Restrictions

CAUTION:

SCSI cables approved by HP are designed to function within the SCSI tolerances for
HP devices. Use of other cables can result in significant problems with system
operation.

The narrow, singled-ended SCSI implemented on C160/C180/C200/C240/
C360 workstations limits the total cable length of narrow SE SCSI cables to
6 meters (19.6 feet).

The fast, wide, differential SCSI definition limits the total cable length of
FW SCSI cables to 25 meters (82 feet).

The ultra, wide single-ended SCSI definition limits the total cable length of
ultra, wide-SE SCSI cables to 3 meters (9.84 feet).

Always use the shortest possible cable(s) for your configuration.

If you are daisy-chaining narrow SE SCSI devices together, use the follow-
ing cables:

92222A cable with 0.5 meter (1.6 feet) length

92222B cable with 1.0 meter (3.2 feet) length

92222C cable with 2.0 meter (6.6 feet) length

If you are daisy-chaining FWD SCSI devices together, use the following
cables:

C2911A cable with 0.9 meter (3 feet) length

C2924A cable with 2.5 meter (8.2 feet) length

C2925A cable with 10.0 meter (32.8 feet) length

C2926A cable with 20.0 meter (65.6 feet) length

If you are daisy-chaining ultra, wide-SE SCSI devices together, use the fol-
lowing cable:

C2978A cable with 0.5 meter (1.64 feet) length

NOTICE

See “Determining SCSI Bus Length” later in this Appendix to determine
the total length of your cables.

Advertising