When Installing Controllers

DO
•

since this is a telephone entry system at least one phone line will be necessary, it is important to plan ahead to meet
power and telephone requirements for your system (if using a modem, the host computer will need 1 phone line,
plus one for each master controller in each network or each EntraGuard unit)

•

mount controllers in environmentally suitable areas - the EntraGuard Gold unit is weather resistant, but care should
be taken to avoid areas of weather/temperature/humidity extremes

•

mount the controller at least 3 feet away from the controller's power supply to prevent EMI radiated from the power
supply from affecting the controller

•

use the enclosure as a mounting template to mark drilling holes for permanent mounting

•

note the locations of the knockouts in the enclosures and remove the appropriate knockout for the easiest cable
routing into the controller

•

route all controllers in a network in a single, continuous daisy-chain (with the EntraGuard Gold controller as the
master)

•

route cables in accessible areas for ease of maintenance

•

connect all controllers to a quality earth ground

1

•

add transient suppression across electric devices attached to a controller output

•

use an isolation relay (P/N IRP-1) if attaching to a parking gate, a turnstile, or any application using a large electric
motor

•

verify the controller's supply voltage is 12 VDC – long power line runs cause a drop in voltage at the end of the run

•

verify proper operation of the host computer's COM port or Ethernet/LAN WAN connection.

DO NOT
•

make modem phone line connections through PBX telephone switching systems - most modems are not compatible
with PBX systems leading to disconnection problems with the modem

•

locate the EntraGuard Gold controller near EMI sources - EMI sources can affect the performance of the controller

•

use switching power supplies - they are EMI sources

•

install the Radiant keypad in a location where there is prolonged, direct sunlight as the keypad may not appear
bright enough

•

route network cables beside power cables - transients on the power cables may be picked-up by network and reader
cables

•

stretch or over-tension cables

•

route over sharp objects

•

let the wires get tangled

•

route the EntraGuard Gold controller as a slave to a PXL-250 master

•

route all controllers in a network in spur, hub, or loop configurations

•

connect earth ground

1

to the network cable shield - the EntraGuard Gold automatically connects earth ground to

the shield at one point on the network to prevent ground loops

•

use gender changer plugs when making RS-232 serial communication connections (unless you know it is a
“straight-through” plug) - gender changers may have internal wiring changes that can disrupt communications

1. Ground wire is green, with or without yellow tracer.