MR16out

DOC 10107-0010

REV 2.01

Page 4

Jumpers:

JUMPER

DESCRIPTION

J1

RS-485 termination, install in first and last units only

J2

Not used

J3

2-wire/4-wire select, install in 2W position only

J4

Factory use only

J5

Factory use only

J6

Factory use only

J7

Factory use only

J8

Factory use only

J9

Factory use only


7. Status LEDs:

Power-

up: All LED’s OFF


Initialization: Once power is applied, initialization of the module begins

When initialization is completed, LEDs A, B, CT, and BA are briefly sequenced ON then OFF.

Run time: After the above sequence, the LEDs have the following meanings:

A LED: Heartbeat and On-Line Status:
Off-line: 1 sec rate, 20% ON
On-line:

Non-encrypted communication: 1 sec rate, 80% ON
Encrypted communication:
.1 sec ON, .1 sec OFF, .1 sec ON, .1 sec OFF, .1 sec ON, .1 sec OFF, .1 sec ON, .3 sec OFF


A LED Error Indication:

Waiting for application firmware to be downloaded: .1 sec ON, .1 sec OFF.

B LED: SIO Communication Port Status:
Indicates communication activity on the SIO communication port

CT: Cabinet Tamper
BA: Power Fault


LED 1 through 16: Illuminates when output relay OUT 1 (K1), OUT 2 (K2) is energized and so on.