0 programming – Keri Systems EntraGuard Bronze Quick Reference User Manual

Page 2

Advertising
background image

P/N 01811-001 Rev. B

5.0

Programming

All operating parameters are programmable from either the EntraGuard Bronze’s front panel
keypad or from any telephone in the residence connected to the same phone line as the
EntraGuard Bronze unit. There are 19 commands available. Listed below are some of the most
commonly used. For more information on programming the EntraGuard Bronze, refer to the
EntraGuard Bronze Quick Start Guide (P/N 01911-001).

When entering programming commands, the unit responds to correct entries with a short, high-
pitched tone to indicate the command was accepted. The unit responds to incorrect/invalid
entries with a short, high-pitched tone followed by a low-pitched tone to indicate the command
was rejected.

1530 Old Oakland Road, Suite 100
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309

Web: http://www.kerisys.com E-mail: [email protected]

Operation

Instructions

To Enter
Progrmming Mode
using Bronze Unit

See the EntraGuard
Bronze Residence
Guide for the pre-
programmed code.

Factory Default =
999999

• Press

.

• Press

– the six-digit programming

code.

• The unit emits a short high-pitched tone to indicate the unit is in programming

mode. If no sound is emitted an invalid programming code has been entered.

To Enter
Progrmming Mode
using Residence
Telephone

See the EntraGuard
Bronze Residence
Guide for the pre-
programmed code.

Factory Default =
999999

• Press

.

• Press

– the six-digit programming

code.

• The unit emits a short high-pitched tone to indicate the unit is in programming

mode. If no sound is emitted an invalid programming code has been entered.

All subsequent commands assume the EntraGuard Bronze unit is in Programming

Mode.

Add an Entry Code

The EntraGuard
Bronze comes with
four entry codes pre-
programmed. See the
EntraGuard Bronze
Residence Guide for
the codes.

Factory Default =
123

• Press

.

• Press

– the desired entry code.

• Press

. The unit emits a short high-pitched tone to indicate the code has

been accepted. A high-low tone is emitted if an invalid programming code has
been entered.

Delete an Entry
Code

• Press

.

• Press

– the entry code to be deleted.

• Press

. The unit emits a short high-pitched tone to indicate the code has

been deleted. A high-low tone is emitted if an invalid entry code has been
entered.

Delete all Entry
Codes

• Press

.

• Press

. The unit emits a short high-pitched tone to indicate all entry codes

have been deleted. A high-low tone is emitted if an invalid entry code has been
entered.

Reset the
EntraGuard Bronze
Unit

• Press

.

• Press

. The unit emits a short high-pitched tone to indicate the unit has

been reset.

Set the Programming
Mode Entry Code

See the EntraGuard
Bronze Residence
Guide for the pre-
programmed code.

Factory Default =
999999

• Press

.

Press

the

desired

six-digit

programming code.

• Press

. The unit emits a short high-pitched tone to indicate the entry code

has been accepted. A high-low tone is emitted if an invalid entry code has been
entered.

Set the Ring Mode

The EntraGuard
Bronze has been pre-
programmed to Type
2.

Factory Default =
Type 1

• Press

.

• Press

– the desired ring mode.

• Type 1: three short rings - long pause
• Type 2: two medium rings - long pause

• Press

. The unit emits a short high-pitched tone to indicate the ring mode

has been accepted. A high-low tone is emitted if an invalid ring mode has been
entered.

Set the Maximum
Number of Rings

Factory Default = 6

• Press

.

• Press

– the desired number of rings.

• Press

. The unit emits a short high-pitched tone to indicate the number of

rings has been accepted. A high-low tone is emitted if an invalid number of rings
has been entered.

Set Gate 1 Relay
Access Code

Factory Default = 9

• Press

.

• Press

– the desired relay access code.

• Press

. The unit emits a short high-pitched tone to indicate the access code

has been accepted. A high-low tone is emitted if an invalid access code has been
entered.

Set Gate 1 Relay
Timeout

Factory Default = 5
seconds

• Press

.

• Press

– the desired relay timeout value.

• Press

. The unit emits a short high-pitched tone to indicate the timeout

value has been accepted. A high-low tone is emitted if an invalid timeout value
has been entered.

Set Gate 2 Relay
Access Code

Factory Default = 2

• Press

.

• Press

– the desired relay access code.

• Press

. The unit emits a short high-pitched tone to indicate the access code

has been accepted. A high-low tone is emitted if an invalid access code has been
entered.

Operation

Instructions

Set Gate 2 Relay
Timeout

Factory Default = 5
seconds

Press .

• Press

– the desired relay timeout value.

• Press

. The unit emits a short high-pitched tone to indicate the timeout

value has been accepted. A high-low tone is emitted if an invalid timeout value
has been entered.

Set Call Forwarding
Telephone Number

Press .

Press

the

desired

forwarding

telephone number (up to 20 digits).

• Press

. The unit emits a short high-pitched tone to indicate the telephone

number has been accepted. A high-low tone is emitted if an invalid telephone
number has been entered.

Enable Call
Forwarding

Press .

• Press

. The unit emits a short high-pitched tone to indicate call forwarding

has been enabled.

Disable Call
Forwarding

Press .

• Press

. The unit emits a short high-pitched tone to indicate call forwarding

has been disabled.

Set Maximum
Connection Time

Factory Default = 60
seconds

Press .

• Press

– the desired maximum connection time.

• Press

. The unit emits a short high-pitched tone to indicate the connection

time has been accepted. A high-low tone is emitted if an invalid connection time
has been entered.