Instruction manual sd, Sauter gmbh – KERN & SOHN SD 3KN150 User Manual

Page 3

Advertising
background image

Sauter GmbH

Ziegelei 1
D-72336 Balingen
E-Mail: [email protected]

Tel: +49-[0]7433- 9933-199
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com

Instruction Manual

SD

SD-BA-e-1213

3

measurement results is sticking out, in the way it comes
out of the small guide trench.
On the right side of the compartment you can find a small
button, which has to be pressed to open the compartment
for changing the paper roll.


The second picture, see below, shows the open paper roll
compartment. It is shown how the paper roll has to be
inserted correctly into the compartment for succeeding
printing operations.
To close it, the button on the right has to be pressed during
closing the compartment. A small piece of paper has to
stick out.








Below you see the printing output with all necessary
information:

5. Warning


Intended use
The instrument you have acquired serves to determine the
measuring value of the material to be measured. It is
intended to be used as a “non-automatic“ instrument, i.e.
the material to be measured is manually and carefully
attached at the instrument. The measuring value can be
read off after a stable measuring value has been obtained.

Inappropriate use
Do not use the instrument for dynamic measuring. In the
event that small quantities are removed or added to the
material to be measured, incorrect measuring results can
be di

splayed due to the “stability compensation“ in the

instrument. (Example: Slow draining off of liquid from a
container suspended from the instrument). Do not attach a
continuous load. This can damage the measuring unit as
well as the parts, relevant to safety.

Prevent jolts, torsion and oscillation (e.g. by appending
slopingly) of all kinds. Be sure to prevent overloading the
instrument in excess of the stated maximum load (max.),
minus any tare weight that may possibly exist. This could
damage the instrument (risk of breakage).

Important:
• Always make sure that there are no people or materials
below the load that could be injured or damaged!
Never operate the instrument in hazardous locations. The
series design is not explosion-proof. Structural alterations
may not be made to the instrument. This can lead to
incorrect measuring results, faults concerning safety
regulations as well as to destruction of the instrument. The
instrument may only be used in compliance with the
described guidelines. Varying areas of application/ planned
use must be approved by SAUTER in writing.

Guarantee
The guarantee is not valid following

• non-observation of our guidelines in the operating
instructions

Advertising
This manual is related to the following products: