10.5. Compressor does not start:
Check the mains electricity. Compressor was overheated and overheating protection switches
it off. Overheating protection needs replacing.

10.6. Compressor switching noise through the speakers:
The compressor has the same effect as household refrigerators which generate noise when
switching on or off. Some systems are more sensitive than others. If possible the compressor
should be connected to a secondary electrical circuit then the audio system. If this is not
possible then the compressor should be as far away as possible from the audio system
connected to the mains. A noise filter on the compressor together with a long mains cable
might help. See also Zero Switching kit: 8.0.