NeoTherm Boilers and Water Heaters

LIGHTING THE UNIT
1. STOP! Read the safety information listed above.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the unit.
4 This unit is equipped with an ignition device which automatically lights the burner.

Do not try to light the burner by hand.

5. Remove the front access panel.
6 Turn off the manual gas valve. The valve is off when the valve handle is at a right

angle to the gas pipe.

7. Wait five minutes to allow any gas to clear. Smell for gas, including the area near

the floor. If you do smell gas, STOP! Follow Step B in the safety information listed

above. If you don’t smell gas, go to the next step.

8. Slowly turn the manual gas valve to “ON.” The handle on the valve will be parallel

to the gas pipe.

9. Replace the front panel.
10. Turn on the electric power to the unit.
11. Set the thermostat to the desired setting.
12. If the unit will not operate, follow the instructions in “Turning Off the Gas to the

Unit” and call your service technician or gas supplier.

Gas inlet

Manual gas valve

shown in the

Off position

TURNING OFF THE GAS TO THE UNIT
1. Before doing any service work, turn off all electric power to

the unit.

2. Set the thermostat to the lowest setting.
3. Remove the front access panel.
4. Turn off the manual gas valve. The valve is off when the

valve handle is at a right angle to the gas pipe.

5. Replace the front panel.

Manual Gas Valve