Electrical Connection: (See Figure 5, 6 and 7)

1.

Remove the two screws attaching the front cover of

the control box.

2.

There are five wires coiled in the area on the right

side of the control box, supplied with wire nuts: 2

black wires twisted together, 2 white wires twisted

together, and a brown wire.

3.

Follow Figures 5, 6 and 7. Remove the wire nut

from the two black wires, and connect the hot lead

from a 115 volt power supply to both wires. Secure

the three wires with the wire nut.

4.

The two white, neutral wires should be joined to the

other neutral lead coming from the 115 volt power

supply, and the neutral lead coming from the pump

(space heating).

5.

The brown wire attaches to the hot side of the space

heating pump.

6.

There is a molex connector located on the left side

of the control panel. Connect the vent damper

harness to the molex connector and the other end to

the vent damper receptacle.

NOTE: The connection in step 6 should remain intact at
all times, otherwise the boiler will not fire.

Some Canadian units are supplied with vent damper

jumper plug. Do not remove jumper unless vent damper

is to be installed.