Ground Control 2.0 Troubleshooting Guide

GROUND CONTROL 2.0

TROUBLESHOOTING GUIDE

Touch Pad Error Codes

NOTE: To clear Error Code, push "ENTER" - If error remains, the code will appear again.

LCD Display Text

What is Happening?

What Should Be Done?

"EXCESS ANGLE"

Unsecured controller.
Uneven or sloped site.

Check and secure controller placement.
Relocate the coach.

"FEATURE DISABLED"

Front of coach below level when

starting Auto Level process.

Raise front of coach above level and restart Auto

Level process.

"LOW VOLTAGE"

Battery voltage has dropped below

necessary operating range.

Check wiring - repair or replace.
Test battery voltage under load - charge or

replace.

"OUT OF STROKE"

Jack has reached maximum stroke

length.

Check disposition of jacks. Relocate the coach.

"EXTERNAL SENSOR"

Bad connection or wiring from the

controller to the rear sensor.

Replace or repair connection to rear remote

sensor.

"JACK TIME OUT"

Time limit exceeded for the

requested auto operation.

Check disposition of jacks.

"COMM ERROR"

Communication between controller

and touchpad has been lost.

Check harness for proper connections or

damage. Replace if necessary.

"CHECK STABILIZER"

Reminder for units equipped with JT

Strong Arm to lock the arms.

Lock the JT Strong Arm assemblies into

place and press FRONT and then REAR to

acknowledge.