NOTE: To clear an error from the touch pad, repair or otherwise correct the issue, then press “ENTER.” If the

error is still present, the message will be displayed again.

LCD Message

What's Happening?

What Should Be Done?

****ERROR****

Excess Angle

Controller not properly secured.

Check and secure controller placement.

Excessive angle reached during

auto operation.

Relocate the coach.

****ERROR****

Excessive Angle

Controller not properly secured.

Check and secure controller placement.

Excessive angle reached during

manual operation.

Relocate the coach.

****ERROR****

Feature Disabled

Front of coach below level when

starting Auto Level process (only

when trying to initiate Hitch

Recognition).

Raise front of coach above level and restart Auto

Level process.

Touch pad power not cycled

between consecutive leveling

operations.

Turn touch pad off and then back on to reset the

system.

Zero point not set.

Set zero point.

****ERROR****

Low Voltage

Battery voltage dropped below

10.8V.

Check wiring for loose connection.

Test battery voltage under load - charge or replace.

****ERROR****

Out Of Stroke

Jack has reached maximum stroke

length and is unable to lift.

Check disposition of jacks. Relocate the coach.

****ERROR****

External Sensor

Bad connection or wiring from the

controller to the rear sensor.

Replace or repair connection to rear remote sensor.

****ERROR****

Jack Time Out

Time limit exceeded for the

requested auto operation.

Check disposition of jacks.

****ERROR****

Auto Level Fail

Unable to auto level due to uneven

ground.

Check disposition of jacks. Relocate the coach.

Unable to auto level due to zero

point being set incorrectly.

Reset zero point.

****ERROR****

Comm Error

Communication between controller

and touch pad has been lost.

Check harness for proper connections or damage.

Replace if necessary.

****ERROR****

Check Stabilizer

Reminder for units equipped with

JT Strong Arm to lock the arms.

Lock JT Strong Arm assemblies into place and press

FRONT and then REAR to acknowledge.

****ERROR****

Bad Calibration

Sensor calibration values are out of

range.

Reset zero point.

****ERROR****

Internal Sensor

Internal sensor problem.

Replace controller.

**PANIC STOP**

Function Aborted

The user pressed a button on the

touch pad during an automatic

operation.

Restart automatic operation and then refrain from

pressing any buttons on the touch pad.