Troubleshooting Chart

Problem

Probable Cause

Corrective Action

System will not turn on and

on/off indicator light does not

illuminate

Coach ignition not in RUN

position

Turn ignition to RUN position

Parking brake not set

Set parking brake

Controls have been on for more

than four minutes and have

timed out

Turn ignition off and then back on

Control pad turns on but turns

off when leg button is pushed

Low voltage on battery

Start coach to charge battery

Control pad turns on, coach will

not auto-level, jacks down light

is on, jacks are retracted

Low fluid level

Check fluid level in reservoir. If fluid is low,

add fluid to FILL TO HERE line on reservoir.

If JACKS DOWN light remains on call

Lippert Service.

Jacks will not extend to ground,

pump is running

Little to no fluid in reservoir

Fill reservoir with DEXRON III ATF

Leg valve is inoperative

Clean, repair or replace

Electronic signal is lost

between control leg valves

Trace wires for voltage drop or loss

of signal. Repair or replace necessary

wires or replace control pad.

Any one or two jacks will not

retract

Hose damaged or

unconnected

Replace with new hose or reconnect

hose

Return valve inoperative

Replace inoperative return valve

Electronic signal is lost

between control and

solenoid

Attempt to retract jacks in manual

mode. If successful, replace control

pad. If not, test for voltage drop

between control pad and leg valve.

Repair bad wiring or replace defective

board or valve.

"Jacks Down" LED does not go

out when all jacks are retracted

Low fluid level

Fill reservoir to proper level with ATF

Retract pressure switch

inoperable

Check connection or replace

Alarm sounds and "Jacks

Down" LED starts flashing

while traveling, jacks are fully

retracted

Low fluid level

Fill reservoir to proper level with ATF

Retract pressure switch

inoperable

Check connection or replace

Jack bleeds down after being

retracted

Manual override valve open

Close override

Control panel powers up; "Low

Voltage" LED flashes

Engine not running

Start coach engine

"Low Voltage" LED is solid

Charging system faulty

Turn key OFF then, back ON again

to reset. Check power and ground

connections on battery, alternator and

chassis.

No Power to control panel

Tripped circuit breaker

Reset circuit breaker

Ignition not on

Turn ignition on