Lippert Components LCI Level-Up Motorhome Leveling (2013-present) User Manual

Page 9

Advertising
background image

Rev: 08.11.2014

LCI Level-Up Motorhome Leveling (2013-Present)

Page 9

Error Text

Description

Excess Angle

Excess slope for auto leveling

Feature Disabled

Control not zeroed

External Sensor

Remote sensor short or disconnected

Out of Stroke

Check campsite for even, level ground and turn engine

on - Check battery voltage under load.

Low Voltage

Turn engine on - Check battery voltage under load.

Function Aborted

Panic stop

Jack Timeout

Auto mode/Retract timeout

Auto Level Fail

Unable to level

Not Configured

Control not zeroed

Zero Not Set

Control not zeroed

Battery Voltage

Turn engine on - Check battery voltage under load

Apply Park Brake to Auto Level

Set parking brake

Unit has retracted for longer than 50

seconds

Retract timeout return leveling jacks for service. Latched

retract mode

Unable to Finish Leveling

Move coach to a more level site

Check Wiring

Touchpad is powered, but not communicating with the

brain. Check pin 1 and 2 of touchpad harness

Caution, Excess Run Time

Pump run too long in manual mode

Latched Retract / Service

Check for leaking jack hose or fitting, reset by pressing

retract and enter at the same time

Low Voltage Signal

1. The vehicle requires 12.7V DC to operate in the AUTO mode. If the voltage is too low, the screen will

display LOW VOLTAGE. If voltage drops below 12.7V DC, the system will only operate in the MANUAL

MODE and continue to display LOW VOLTAGE.

2. Minimum Voltage - If voltage drops below 9.5V DC during AUTO or MANUAL operation LOW VOLTAGE

will appear in the screen and the system will cease operating.

Excess Angle

1. The control will not operate at extreme slopes, i.e. 3.5 degrees fore and aft and 3.5 degrees side to

side.

2. If the coach indicates “EXCESS ANGLE” or “JACKS STROKED OUT“ during an auto level cycle, move the

coach to a more level spot.

Error Mode

NOTES:
• If an error occurs before or during operation, the error will be displayed in the LCD and an alarm will

sound. To reset all error or service displays, push RETRACT and ENTER at the same time.

• All normal functions will be disabled when the system is in Error Mode.
• Auto Level can only commence if running voltage is 12.7V DC or above.
• Auto Level operation will halt if running voltage drops to 9.5V DC.
• Manual Level operation can be performed at all running voltages above 9.5V DC.

Operation