OPERATION-HYDRAULIC LANDING GEAR

WARNING

FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY
RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

ALWAYS MAKE SURE THAT THE LANDING GEAR AREA IS CLEAR OF
PEOPLE AND OBJECTS BEFORE AND DURING OPERATION OF THE
LANDING GEAR.

ALWAYS KEEP AWAY FROM THE LANDING GEAR WHEN THE SYSTEM IS
BEING OPERATED. SERIOUS PERSONAL INJURY OR DEATH MAY OCCUR.

BE SURE LANDING SYSTEM CONTROLS ARE IN THE MANUAL OVERRIDE
POSITION WHEN TRAVELING (SEE Fig. 5c).

The Lippert Hydraulic Slideout and HLG System employs a system of manually
leveling the unit. The control panel for the landing gear is located on the outside
of the unit in it’s own compartment with 3 switches: One (1) for the front landing
gear, Fig. 5a, one (1) for the rear landing gear, Fig. 5b and one (1) 12V
disconnect for the system to prevent the landing gear from extending during
travel, Fig. 5c.

Utilize a carpenter’s level when leveling the unit. Set the level on the floor and
take note of the position of the bubble in both the front to back reading and the
side to side reading. It is best to set up the unit on the most level site available.
The system is set up to level the unit from front to back so it is important to get
the unit as level as possible side to side prior to using the landing gear.

FIG. 5 - LEVELING CONTROL PANEL

12V DISCONNECT

5a

5b

5c