Schwintek in-wall™ troubleshooting guide – Lippert Components Schwintek In Wall Slide-Out System User Manual

Page 3

Advertising
background image

Rev: 01.30.2015

Page 3

Lippert In-Wall Troubleshooting Guide

Fig. 1 - Controller

A

C

B

D

E

Controller (Fig. 1)

Callout

Description

A

Motor 1 Junction

B

Motor 2 Junction

C

Switch Junction

D

Power Junction

E

Controller LED

Display

System Inoperative
Controller

1. Locate Controller (Fig. 1).
2. Activate switch.
3. Look for the status LEDs on the controller to light while switch is activated (Fig. 1E).
4. If status LEDs light, but no error codes are present, skip to page 9 of this guide to do a visual inspection

of the mechanical portions of this system.

5. If status LEDs do not light, and no error codes are present, check the following:

A. Check for 12VDC in to controller (red and black terminals) (Fig. 1D).
B. Check for 12VDC at switch connection on both extend and retract (Fig. 1C).
C. Check the battery for 12VDC.

6. If error codes are present, refer to the label on the controller for error identification.

SCHWINTEK IN-WALL™ TROUBLESHOOTING GUIDE