Lippert In-Wall Troubleshooting Guide

Room Stuck Out (Retail)
Electronic Manual Override

1. Locate the controller.
2. Press the "mode button" six times quickly. Press and hold a seventh time for approximately five

seconds (Fig. 3).

3. The red and green LED lights will begin to flash, confirming the override mode.
4. Release mode button.
5. Use the normal slide-out control switch to retract the room.

NOTE: If wall switch is not pushed within 60 seconds of entering the electronic manual override mode, the

controller will revert to normal operating mode. No action is required to return to normal operating

mode.