Local loopback, Remote loopback, Warning – Longshine LCS-C842SC User Manual

Page 9

Advertising
background image

Enhanced 10/100Base-TX to 100Base-FX Converter

- 13 -

Local Loopback

1.

Test Condition setup

– for the function to produce

an accurate result, be sure to set switches

according to the table below:

Test Condition

2.

Launch a loopback or diagnostics testing program

and follow the instructions given. Typically, the

instructions will be similar to the following:

a.

Enter the number of test messages

(frame packets) to be sent (Between 1

1000)

b.

Click on the START button

c.

The program will send a

testing

message looped in the copper segment,

and display a pass/fail result

DIP Switches

1

2

3

4

5

6

7

Converter A

OFF

FD

100

FD

OFF

ON

OFF

Converter B

OFF

FD

100

FD

OFF

OFF

OFF

Enhanced 10/100Base-TX to 100Base-FX Converter

- 14 -

Remote Loopback

1.

Test Condition setup

– In order for the function to

produce an accurate result, set switches
according to the table below:

Test Condition

2.

Launch a loopback or diagnostics testing program
and follow the instructions given. Typically, the
instructions will be similar to the following:

a.

Enter the number of test messages
(frame packets) to be sent (Between 1

1000)

b.

Click on the START button

c.

The program will send a testing
message looped in the fiber segment,
and display a pass/fail result

NOTE: On a PC, use a program such as Sniffer to conduct the tests.

Other methods include the use of SmartBits series testing
equipment. If you do not have access to either method,
please contact your vendor for advice.

DIP Switches

1

2

3

4

5

6

7

Converter A

OFF

FD

100

FD

OFF

OFF

OFF

Converter B

OFF

FD

100

FD

OFF

OFF

ON

Warning

Be sure to deactivate both local and remote

both loopback test functions for normal converter operations