Maxim Integrated 6612_OMU_S2_URT_V1_13 User Manual

Page 35

Advertising
background image

FDD_6612_ 010

6612_OMU_S2_URT_V1_13 Firmware Description Document

Rev. 1.1

35

Output

Location

(hex)

LSB

Comment

Example

Irms_nb T

Max

8B

mArms

Maximum combined outlet

narrowband rms current measured.

If the largest narrowband current

measured on both outlets is 30

Amps

)8B?<CR>

Returns:

+30.000

VARs_nb T

Min

8C

mW

Minimum combined outlet

narrowband reactive power

measured (per second).

If the largest narrowband VARs

measured on both outlets is 80

VARs

)8C?<CR>

Returns:

+80.000

VARs_nb T

Max

8D

mW

Maximum combined outlet

narrowband reactive power

measured (per second).

If the largest narrowband VARs

measured on both outlets is 300

VARs

)8D?<CR>

Returns:

+300.000

VAs_nb T

Min

8E

mW

Minimum combined outlet

narrowband apparent power

measured (per second).

If the smallest narrowband VAs

measured on both outlets is 80

VARs

)8E?<CR>

Returns:

+80.000

VAs_nb T

Max

8F

mW

Maximum combined outlet

narrowband apparent power

measured (per second).

If the largest narrowband VAs

measured on both outlets is 300

VARs

)8F?<CR>

Returns:

+300.000


Advertising