Milwaukee Tool 9096-20 User Manual

Page 3

Advertising
background image

4

5

SPECIFIC SAFETY RULES

SPECIFICATIONS

•Hold power tool by insulated gripping surfaces,

when performing an operation where the fas-
tener may contact hidden wiring.
Fasteners
contacting a “live” wire may make exposed metal
parts of the power tool “live” and could give the
operator an electric shock.

Maintain labels and nameplates. These carry

important information. If unreadable or missing,
contact a MILWAUKEE service facility for a free
replacement.

WARNING: Some dust created by power sanding,

sawing, grinding, drilling, and other construction
activities contains chemicals known to cause
cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:

• lead from lead-based paint
• crystalline silica from bricks and cement and
other masonry products, and
• arsenic and chromium from chemically-treated
lumber.
Your risk from these exposures varies, depending

on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are spe-
cially designed to fi lter out microscopic particles.

SYMBOLOGY

Double Insulated

Amperes

Volts

Alternating Current

Alternating Current/Direct
Current

Impacts per Minute Under
Load (IPM)

Underwriters Laboratories, Inc.
United States and Canada

Mexican Approvals Marking

Cat. No.

Volts

A

No Load

RPM

Drive Shank

Impacts Per

Minute

Average Torque

Output

9070-20
9071-20
9072-20
9072-22
9075-20
9092-20
9096-20

120 AC Only
120 AC Only
120 AC Only
120 AC Only
120 AC Only
120 AC Only
120 AC Only

7
7
7
7
7
7
7

1800
1800

600-1800
600-1800

1800

600-1800
600-1800

1/2"
1/2"
1/2"
1/2"
3/4"

7/16" Hex

5/8" Hex

2600
2600

1000-2600
1000-2600

2500

1000-2600
1000-2600

300 ft-lbs.
300 ft-lbs.

100-300

ft-lbs.

100-300

ft-lbs.

380 ft-lbs.

100-315

ft-lbs.

100-315

ft-lbs.

Fig. B Fig. C

Fig. A

GROUNDING

WARNING

Improperly connecting the

grounding wire can result in the risk of elec-
tric shock. Check with a qualifi ed electrician
if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug
provided with the tool. Never remove the
grounding prong from the plug. Do not use
the tool if the cord or plug is damaged. If
damaged, have it repaired by a MILWAUKEE
service facility before use. If the plug will not
fi t the outlet, have a proper outlet installed by
a qualifi ed electrician.

Grounded Tools: Tools with Three Prong Plugs
Tools marked “Grounding Required” have a three
wire cord and three prong grounding plug. The
plug must be connected to a properly grounded
outlet (See Figure A). If the tool should electrically
malfunction or break down, grounding provides a
low resistance path to carry electricity away from
the user, reducing the risk of electric shock.
The grounding prong in the plug is connected
through the green wire inside the cord to the
grounding system in the tool. The green wire in the
cord must be the only wire connected to the tool's
grounding system and must never be attached to
an electrically “live” terminal.
Your tool must be plugged into
an appropriate outlet, properly
installed and grounded in accord-
ance with all codes and ordinances.
The plug and outlet should look like
those in Figure A.

Double Insulated Tools:
Tools with Two Prong Plugs
Tools marked “Double Insulated” do not require
grounding. They have a special double insula-
tion system which satisfi es OSHA requirements
and complies with the applicable standards of
Underwriters Laboratories, Inc.,
the Canadian Standard Asso-
ciation and the National Elec-
trical Code. Double Insulated
tools may be used in either of
the 120 volt outlets shown in
Figures B and C.

Grounded tools require a three wire extension
cord. Double insulated tools can use either a two
or three wire extension cord. As the distance from
the supply outlet increases, you must use a heavier
gauge extension cord. Using extension cords with
inadequately sized wire causes a serious drop in
voltage, resulting in loss of power and possible tool
damage. Refer to the table shown to determine the
required minimum wire size.
The smaller the gauge number of the wire, the
greater the capacity of the cord. For example, a 14
gauge cord can carry a higher current than a 16
gauge cord. When using more than one extension
cord to make up the total length, be sure each cord
contains at least the minimum wire size required.
If you are using one extension cord for more than
one tool, add the nameplate amperes and use the
sum to determine the required minimum wire size.

Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be

sure it is marked with the suffi x “W-A” (“W” in
Canada) to indicate that it is acceptable for outdoor
use.

• Be sure your extension cord is properly wired

and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a
qualifi ed person before using it.

• Protect your extension cords from sharp objects,

excessive heat and damp or wet areas.

READ AND SAVE ALL

INSTRUCTIONS FOR FUTURE USE.

* Based on limiting the line voltage drop to fi ve volts at

150% of the rated amperes.

EXTENSION CORDS

Recommended Minimum Wire Gauge

For Extension Cords*

Extension Cord Length

Nameplate

Amperes

25'

50'

75'

100'

150'

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

18
18
18
18
16
14
12

18
18
18
16
14
12
10

18
18
16
14
12
10

--

18
16
14
12
10

--
--

16
14
12
12

--
--
--

Cat. No.

Quick Change

Auger Bits

Selfeed Bits

9070-20
9072-20
9072-22
9092-20
9096-20

1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"

2-9/16"
2-9/16"
2-9/16"
2-9/16"
2-9/16"

FUNCTIONAL DESCRIPTION

1. Drive shank
2. Forward/reverse switch

(9072-20, 9072-22, 9092-20, 9096-20)

3. Trigger

(9072-20, 9072-22, 9092-20, 9096-20)

Rocker

switch

(9070-20, 9071-20, 9075-20)

4. Speed control dial

(9072-20, 9072-22, 9092-20, 9096-20)

5. Quik-Lok

®

cord

(9072-20, 9072-22, 9092-20, 9096-20)

6. Quick change chuck

(9092-20, 9096-20)

7. Tool hanger

(9092-20, 9096-20)

8. Tool hanger ring

(9092-20, 9096-20)

Cat. No. 9072-20,

9072-22

Cat. No. 9092-20

Cat. No. 9075-20

6

7

8

3

1

2

3

4

5

* Only for use with the 7/16" or 5/8" Hex Quick Change

chuck, standard equiptment on the 9092-20 (7/16") and
9096-20 (5/8"), optional accessory (Cat. No. 48-66-0061)
on other models.

QUICK CHANGE CHUCK

CAPACITIES*

Advertising
This manual is related to the following products: