Milwaukee Tool 2237-20NST User Manual

Page 3

Advertising
background image

4

5

OPERATION

ASSEMBLY

Symbology

General Specifi cations

FUNCTIONAL DESCRIPTION

Loading/Changing the Batteries
Replace batteries when the Low Battery indicator

is displayed.

1. Turn Rotary Dial to OFF

and disconnect the test
leads.

2. Unscrew and remove

battery door.

3. Insert two (2) AA bat-

teries, according to the
polarity marked in the
battery compartment

4. Close the battery door and tighten screw se-

curely.

WARNING

To avoid an electrical hazard, turn the Rotary
Dial to OFF and disconnect the test leads
before replacing batteries.

Read Operator’s Manual

Double insulation

Risk of electric shock

Indicates that this instrument can
clamp on bare conductors when mea-
suring a voltage corresponding to the
applicable measurement category,
which is marked next to this symbol.

Earth

Danger, Warning, or Caution

Battery compartment

European Conformity Mark

Underwriters Laboratories, Inc.,
United States and Canada

Cat III

Classifi cation of transient overvolt-
ages, based on nominal line voltage
to earth.

1. Current sensing jaws
2. NCVD indicator
3. Jaw opening trigger
4. Rotary Dial
5. Display
6. Zero button

1

3

10

11

5

9

7

6

4

4

2

Cat. No.
2237-20

Cat. No.
2236-20

Accuracy is specifi ed for 1 year after calibration, at
operating temperatures of 18°C to 28°C (64°F to
82°F), with relative humidity at 0 % to 85 %.
Maximum voltage between any terminal and

earth ground

.... 600 V

Jaw Opening (maximum conductor size)

....

approx. 1.3” (33 mm)

Temperature

....

Operating: -10°C to 50°C (14°F to 122°F)
Storage: -40°C to 60 °C (-40°F to 140°F)
Temperature Coefficient

.... 0.1 x (specified

accuracy)/°C (<18°C or >28°C)

Operating Altitude

.... 2,000 meters

Drop Test

.... 1 Meter

Battery

.... 2 AA, NEDA 15 A,IEC LR6

Battery Life

.... Approx. 30 Hours all lights on.

Safety Compliances

.... EN61010-1,

UL 61010-1, EN61010-031 (Probes),

IEC 61010-2-32 (Clamp Assemblies),

IEC/EN 61010-1 2nd Edition for measurement

Category III, 600 V,

Pollution Degree 2, EMC EN61326-1
Certifi cations

.... cULus, CE

7. °F/°C button (2236-20)
Hz button (2237-20)

8. Terminal inputs
9. Min/Max button
10.Worklight LED
11.Hold button

DANGER

To avoid electrical shock:

Never make measurement on a circuit

in which voltage over AC600V exists. Clamp
tips are designed not to short the circuit under
test. If equipment under test has exposed
conductive parts, however, extra precaution
should be taken to minimize the possibility of
shorting.
Do not use with the Battery Cover removed.
Disconnect the test leads from the instrument
for current measurement.

Before Use

Confi rm the Rotary Dial is set to the correct position,

the instrument is set to the correct measurement

mode, and the Data hold function is disabled. Oth-

erwise, desired measurement cannot be made.

LCD Backlight

The LCD backlight will turn off after about 3 minutes

of inactivity. Push any button or turn the rotary dial

to turn the backlight on.

Making a Measurement

AC Current

WARNING

Only

use

MILWAUKEE test leads with

the MILWAUKEE Clamp Meters.
Inspect test leads before each use. Use clamp
meter to run a continuity test.

1. Set the Rotary Dial to position.

AC mark is displayed.

2. Press the jaw opening trigger to

open the jaws and clamp them

onto the conductor under test.

The reading is displayed.

Cat. No. 2237-20 only: Pressing

the “Hz” Key toggles the reading

between AC Current and Hz.

NOTE: Hz Function requires 50A

or more.

NOTE:

Do not clamp over 2 or

more wires at the same time.

Irregular results will occur.

DC Current (Cat. No. 2237-20 only)

CAUTION

Maximum conductor size

is about 1.3" diameter. During measure-

ment, keep the jaws fully closed to ensure
accurate measurements.

DANGER

To avoid electrical shock:

Never make measurement on a circuit

in which voltage over AC600V exists.
Do not use with the Battery Cover removed.

1. Set the Rotary Dial to position.

DC mark is displayed.

2. With the jaws closed and without

clamping them around a conduc-

tor, press the ZERO key to zero

adjust the display.

3. Press the jaw opening trigger to

open the jaws and clamp them

around the conductor under test.

The reading is displayed.

NOTE:

Do not clamp over 2 or

more wires at the same time.

Irregular results will occur.

4. Set the Rotary Dial to an appro-

priate position according to current under test.

5. Press the ZERO key again to release the ZERO

function.

CAUTION

When current fl ows from

the display side to the underside of

the meter, the polarity is positive; fl ow from
underside to display side, the polarity is
negative.

DANGER

To avoid electrical shock:

Never make measurement on a circuit

in which voltage over AC600V exists.
Do not use with the Battery Cover removed.
Keep fi ngers away from jaws during mea-
surements.

AC Voltage

8

1. Set the Rotary Dial to

position.

2. Connect the red test lead

to the VΩ terminal and the

black test lead to the COM

terminal.

3. Connect the test leads to

the circuit under test. The

reading is displayed.

Cat. No. 2237-20 only:

Pressing the Hz Key toggles

the reading between AC

Voltage and Hz. NOTE: Hz

Function requires 70V or
more.

CAUTION

Readings of frequency may fl uctuate or be
infl uenced in noisy environments.

AC