6

7

1. Set the Rotary Dial to position.

2. Connect the red

test lead to the VΩ

terminal and the

black test lead to

the COM termi-

nal.

3. Connect the red

test lead to the

positive (+) side

and black test

leads to the nega-

tive (-) side of the

circuit under test.

The reading is displayed. A reversed connection

is indicated as a negative value.

DANGER

To avoid electrical shock:

Never make measurement on a circuit in
which voltage over DC600V exists.
Do not use with the Battery Cover removed.
Keep fi ngers away from jaws during mea-
surements.

DC Voltage

Resistance/Continuity/Capacitance
Measurements

DANGER

To reduce the risk of electric shock for
Resistance, Continuity, and Capacitance
measurements, never use the meter on an
energized circuit. Make sure a capacitor is
fully discharged before touching or attempt-
ing to make a measurement.
Do not use with the Battery Cover removed.

Resistance

1. Set the Rotary Dial to

position.

2. Connect the red test

lead to the VΩ ter-

minal and the black

test lead to the COM

terminal.

Confi rm “OL” is indi-

cated on the display,

and then short-circuit

the tips of test leads

to make the indica-

tion zero.

3. Connect the test

leads to both ends of the resistor under test.

4. The reading is displayed.

CAUTION

After shorting the test leads, the displayed
value may not be zero due to the resistance
of test leads themselves.

Continuity

1. Set the Rotary Dial to

position.

2. Connect the red test lead

to the VΩ terminal and the

black test lead to the COM

terminal.

Confi rm “OL” is indicated on

the display, and then short-

circuit the tips of test leads

to make the indication zero.

A buzzer will sound.

3. Connect the test leads to

both ends of the conductor
under test. If the resistance under test is 35 ±10Ω
or 25Ω or less, the buzzer will sound.

Capacitance

1. Set the Rotary Dial to

position.

2. Connect the red test lead to the VΩ terminal and

the black test lead to the COM terminal.

3. Discharge capacitor.
4. Connect the test leads to both ends of the capaci-

tor under test.

5. The reading is displayed.

DC Current (Cat. No. 2236-20 only)

DANGER

To avoid electrical shock:

Never make measurement on a circuit in
which voltage over AC600V exists.
Do not use with the Battery Cover removed.

1. Set the Rotary Dial to

position. DC mark

is displayed.

2. Connect the red test

lead to the VΩ ter-

minal and the black

test lead to the COM

terminal. Contact the

red test lead to the

fl ame sensor probe

and the black test

lead to the control

module.

3. Turn on the heating unit. The reading is dis-

played.

Flame

sensor

probe

Control
Module

1. Set the Rotary Dial to

position.

2. Connect the K-type Tem-

perature Probe to the input

terminal. The positive (+)

side of Probe should be

connected to VΩ.

3. Place the probe sensor in

the desired location.

4. The reading is displayed.

CAUTION

The Data Hold readings are released when the
meter enters Sleep Mode.

Worklight LED ON/OFF

To turn the light on and off, press the

button.

HOLD Key
Data Hold Function - Freezes the value on the

display. Press the “HOLD” button to freeze the

reading. The reading will be held regardless of

subsequent variation in input. HOLD is displayed

with the reading. To exit Data Hold mode, press the
HOLD button again.

WARNING

Never connect the Temperature Probe to an
energized circuit.

CAUTION

When the Rotary Dial is set to , the room
temperature should be displayed. If anything
else is displayed, something may be wrong
with the meter. Stop using the meter imme-
diately.

Sleep Mode
The clamp meter is automatically powered off in

about 20 min after the last Rotary Dial or button

operation. To reset, rotate the Rotary Dial to OFF.

If the display is still blank when a new Rotary Dial

setting is selected, replace the batteries.
The sleep mode is disabled when the MIN/MAX

function is selected.
The clamp meter does use battery power in sleep

mode. Be sure to switch the tool to OFF to conserve

battery power.

Temperature (Cat. No. 2236-20 only)

DANGER

The LED may not be displayed due to instal-
lation condition of electrical circuit or equip-
ment. Never touch the circuit under test to
avoid possible danger even if the LED for
NCVD is not displayed.
Check the functionality of LED on a well-
known power supply prior to measurement.
When the LED doesn’t light up, do not make
measurement.
NCVD indication is affected by external volt-
age, and how the meter is held or placed.

When the meter is on in any

function, the non-contact volt-

age detector will indicate with a

Red LED on the display when

an electric fi eld exceeding 90V

is detected. Place the edge of

the jaw labeled “Voltage Detec-

tor” near the electric fi eld.

Over-fl ow indication
Any time the input exceeds the

measuring range “OL” or “-OL” is displayed.

CAUTION

Clamp the jaws around the conductor under
test and press the MIN/MAX button after an
appropriate range is selected by Auto-rang-
ing function. ZERO and Hz keys are disabled
while MIN/MAX Function is active.

MIN/MAX Function
The MIN/MAX function can be

used during measurements of AC

or DC current, AC or DC voltage,

Temperature (2236-20 only), uA DC

(2236-20 only), and Resistance.

The MIN/MAX function does not

work in the Capacitance or Continu-

ity measurements.
To measure the minimum or maxi-

mum of the function, set the dial to

the appropriate dial position and

then press the MIN/MAX button

to capture the maximum reading.

Press the MIN/MAX button again to

capture the minimum reading.
Press the MIN/MAX button to toggle between

minimum or maximum. The minimum or maximum

reading is displayed and held until the MIN/MAX is

turned off by holding in the MIN/MAX button for 2

seconds or changing the Rotary Dial position.

Non-Contact Voltage Detection (NCVD)