NORAC UC4+BC+HD5 Part 1 User Manual

Page 24

Advertising
background image

20

11. Connect the black wire with spade connector on C12 to the GND on the DAH09 board (Figure

22).

Figure 22: DAH09 PCB for Autoslant

12. Configure the system for Autoslant by setting the DIP switches on DAH09 board:

a) Set DIP switches 2,3,4,5,6, and 8 to ON. Set DIP switch 7 to OFF (Figure 23).

Figure 23: Suggested Default Setting for DIP Switches 2-8 for AUTOSLANT

b) If the sprayer uses a DAH valve block set DIP switch 1 to OFF. If the sprayer uses a DH valve

block set DIP switch 1 to ON. See Figure 24.

Figure 24: HARDI DAH (DIP 1 OFF) vs. DH Block (DIP 1 ON)

13. Close the electronics enclosure. Gather up excess cable (C11 & C02) and neatly cable-tie to the

machine.

DB15

DIP switches

12 VDC and GND