7 electrical installation – NORAC 5467BC-4B-JD10 User Manual
Page 19

16
7 Electrical Installation
1. Locate the valve module installed on the NORAC valve block. Remove the plugs installed
in positions 7 and 8.
2. Connect the 2 pin connector on cables C10 into positions 7 and 8 on the valve module.
Connect the other end of cables C10 to the 2 pin connectors on the NORAC expansion
block (V02).
3. Disconnect and remove the two NORAC roll sensors (small rectangular box with a cable
running from it). See Figure 14 for locations.
Figure 14: Roll Sensor Locations
4. Connect the active roll sensor (E05) to the 8-way coupler (E11) where one of the roll
sensors was connected using cable C03 and a 2-way coupler (E12). Plug the unused
connector where the second roll sensor was connected using the 6-pin plug.