3 sprayer manual boom height switches – NORAC UC5-BC-AL Quick Guide User Manual

Page 10

Advertising
background image


7

4.3 Sprayer Manual Boom Height Switches

When a manual switch is pressed, an arrow will be displayed on the screen showing which
function is being activated. For example, if the left up switch is pressed then an up arrow will

be shown above the left boom.

Tilt (Variable Geometry) Switches:
While in Automatic Mode if either left or right tilt switches are pressed, the corresponding
boom section will go into Manual Mode. To return all boom sections to Automatic Mode,
press the Auto button. If the Double Tap Wings function is enabled, the tilt down switches can
be used to resume Automatic Mode.

Main Lift Switch:
While in Automatic Mode if the main lift up or down switch is momentarily pressed, the Target
Height is incrementally adjusted up or down.
Pressing and holding the main lift switch will always put the system into Manual Mode. If the
Double Tap Main function is enabled, the main lift down switch can be used to resume
Automatic Mode.

* Some sprayer types may not have all the functionality listed above.

Advertising