4 operation, 1 main run screen – NORAC UC5-BC-AL Quick Guide User Manual

Page 8

Advertising
background image


5

4 Operation

4.1 Main Run Screen

The majority of functional settings and controls can be accessed on the main run screen. An
image of the boom, with the height of each boom section is displayed.
To change between Automatic and Manual Mode, press the corresponding button. When the
boom is blue, the UC5 system is in Automatic Mode. When the boom is black, the UC5
system is in Manual Mode. If the boom is above normal working height, a warning message will
appear requiring permission to allow Automatic Mode.
When the UC5 Height Control system is in Automatic Mode, arrows will appear on the screen
above or below the boom sections. These arrows indicate the UC5 system is making a
correction to part of the boom in the displayed direction. Often times the correction will be
very small and there may not be a noticeable change in boom position.



Figure 2: Main Run-Screen

The height displayed on the boom is measured from the spray nozzles to the soil (Soil Mode)
or to the crop canopy (Crop Mode). If there are five height sensors on the sprayer, the height
displayed is the average for each boom section.

Auto / Manual

Button

Settings

Advertising