Type of cable detected

5E, 6E

Ambient temperature in work

-10℃~+60℃

Tester Port

Tester RJ45 master port (M), tester LOOPBACK RJ45 port (L),

hunting RJ45 port(SCAN);

Remote identifier RJ45 port (R)

The extra BNC and RJ11 converters are used to measure and check

the continuity of coaxial cable and telephone line.

Length Measurement of Twin Twisted Cable

Scope: 1~350 M ( 3 ~1000 ft)

Calibration accuracy: 3% (+/- 0.5M or +/- 1.5 ft) (calibrating cable > 10 M)

Shipment accuracy: 5% (+/- 0.5 M or +/- 1.5 ft). (AMP, AT&T Class 5

cable)

Display: M or ft.

Length Calibration:

User can set calibration factor by himself with a given length cable.

The length of calibrating cable is more than 10 M.

Wire Sequence and Locating Cable Error:

Check errors such as open circuit, short circuit, reverse connection,

cross-over

Automatic Time-delay Shut Off Time:

The tester does not operate for 30 minutes.