页 13, Led indicate testing result as below – NOYAFA NF-HDMI-II User Manual

Page 13

Advertising
background image

Your excellent helper in cable test!

12

Open: Master unit and Remote unit both no connected

pins LEDs are off. (Fig 8.)

Short: Master unit testing short pin LEDs brighter

than others. Remote unit shorted pins LEDs are off.
(Fig 9.)

Crossover: It can't be tested on this mode.

Master unit with Remote unit slow continuity
scan testing function:

1.Press “ TEST button during LED indicate automatic
testing result or Press twice “ TEST” button before LED
off for perform automatic testing, it will continually scan
#1~#19 pin and shield conductor. Master unit and
Remote unit both #1~19 and Shield LEDs will light up in
sequence very slow and sustained repeated automatic
scan.

2.LED indicate testing result as below

: Master unit and Remote unit both testing

pins

#1~19 and Shield LEDs are all lighted up in sequence.

(Fig 7.)

Open: Master unit and Remote unit both LEDs are

off when scan to no connected pins, others LEDs are
all lighted up in sequence. Example : Test HDMI
(A Type) to HDMI (A Type) cable that pin #2、#5、#8、
#11 are not connected, or test HDMI (A Type) to
Mini-HDMI (C Type) cable that pin #1、#4、#7、#10
are not connected, or test Mini-HDMI (C Type) to
Mini-HDMI (C Type) cable that pin #1、#4、#7、#10
are not connected. (Fig 8.)

Straight