Quality of Electrical Wiring and Service

Wiring should be up to current NEC standards and have verified good

AC grounds. It is important that your computer system be plugged into

a grounded AC outlet when charging and that all peripherals connected

to your system reference the same AC ground.

Selecting the Right Equipment

There are a number of companies that sell quality surge suppressors

such as Sutton Designs, APC, and Panamax. When you are looking for

a surge suppressor, consider these things.

Expect to pay at least $50 for a good quality surge suppressor.

The surge suppressor should be a UL 1449, 497, and 1283 listed

for surge suppression, modem surge protection, and RFI/EMI noise

filtering respectively.

The surge suppressor should have diagnostic LEDs that verify good

AC ground, proper wiring, and proper surge operation. Lighted on/off

switches are not recommended since they can produce electrical

noise.

The Joule ratings should be a minimum of 480 Joules for the AC

surge circuit.

The Joule ratings should be a minimum of 240 Joules for the

modem.

The modem surge circuit should present low capacitance to the

modem line or it will slow the transmission rate. Capacitance should

be specified at less than 50 picofarads.

Quality surge suppressor manufacturers generally offer a lifetime

warranty.

Consider obtaining a protected equipment coverage policy which

insures the equipment in the event of surge damage.

The devices that will be attached to the computer also need to be

surge protected.