Broadmore 1750 - Release 4.6

7-41

Configuration

OC-12c/STM-4c BITS/Timing Redundancy

2. Follow the sequence below to set the clock mode configuration on the port of

interest.

3. Follow the sequence below to set the OC12 transmit timing to either recovered

or local/BITS. Recovered clock derives timing from the SONET stream.
Local/BITS derives timing from the onboard oscillator. Repeat this step for
both OC12s.

Follow the sequence below to enable an alarm for loss of BITS clock. Do this for both
OC-12c/STM-4cs.

Select System Management

↵

Select Configure

↵

Select Slot with DS3

↵

Select Port of interest

↵

Choose the BITS option to allow the DS3 port

to derive clock from either BITS or the cell bus

Select Operational Configuration

↵

Select Clock Mode

↵

Select System Management

↵

Select Configuration

↵

Select Slot with OC12

↵

Select Transit Timing

↵

Choose Recovered or Local/BITS

↵

Select System Management

↵

Select Configuration

↵

Select Slot with OC12

↵

Select BITS Clock Alarm Loss

↵

Choose Enable or Disable

↵