FIGURE 10: PILOT VALVE

STEP 13

Refer to FIGURE 11, Note (X). The piezoelectric igniter cannot be installed incorrectly unless
it is damaged. The piezoelectric igniter should be in a parallel plane to the pilot flame diffuser
body. Each time the igniter button is pressed, a blue arc should occur from the piezoelectric
igniter to the pilot flame diffuser body. Replace the burners, the ember tray, the logs, the
embers, and the door, ensuring correct position of all components.