15- ENG

A08597

MAINTENANCE

Customer Responsibilities

Daily

or after

each

use

Before
each
use

Check Safety Valve
Drain Tank

NOTE: See "Operation" section for
the location of controls.

Risk of Unsafe

Operation. Unit

cycles automatically when power is

on. When performing maintenance,

you may be exposed to voltage

sources, compressed air, or

moving parts. Personal injuries

can occur. Before performing any

maintenance or repair, disconnect

power source from the compressor

and bleed off all air pressure.

To Check Safety Valve

Risk of Bursting.

If the safety valve

does not work properly, over-

pressurization may occur, causing

air tank rupture or an explosion.
1. Before starting compressor, pull

the ring on the safety valve to

make sure that the safety valve

operates freely. If the valve

is stuck or does not operate

smoothly, it must be replaced

with the same type of valve.

To Drain Tank

1. Set the On/Auto/Off lever to

"OFF".

2. Turn the regulator knob counter-

clockwise to set the outlet
pressure to zero.

3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing

air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.

5. Drain water from air tank by

opening drain valve (counter-
clockwise.

Risk of Bursting.
Water will

condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
6. After the water has been drained,

close the drain valve (clockwise).
The air compressor can now be
stored

NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.