Service and adjustments – Craftsman 919.16644 User Manual

Page 16

Advertising
background image

16- ENG

A08597

SERVICE AND ADJUSTMENTS

5. Unscrew the check valve (turn

counterclockwise) using a 7/8"
open end wrench.

Note the

orientation for reassembly.

6. Using a screwdriver, carefully

push the valve disc up and

down.

NOTE: The valve disc

should move freely up and down

on a spring which holds the valve

disc in the closed position; if

not the check valve needs to be

cleaned or replaced.

7. Clean or replace the check

valve. A solvent, such as paint or

varnish remover can be used to

clean the check valve.

8. Apply sealant to the check valve

threads. Reinstall the check valve

(turn clockwise).

9. Replace the pressure release

tube. Tighten nuts.

10. Replace the outlet tube and

tighten nuts.

11. Perform the Break-in Procedure.

See "Break-in Procedure" in the

Operation section.

To Replace or Clean Check

Valve

1. Release all air pressure from air

tank. See "To Drain Tank" in the

Maintenance section.

2. Set the On/Auto/Off lever to

"OFF" and unplug unit.

3. Loosen the nut on the outlet tube

and move the outlet tube to the
side.

4. Loosen the nut on the outlet tube

and move the outlet tube to the
side.

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

Risk of Unsafe

Operation. Unit

cycles automatically when power

is on. When servicing, you may

be exposed to voltage sources,

compressed air, or moving parts.

Before servicing unit unplug or

disconnect electrical supply to

the air compressor, bleed tank

of pressure, and allow the air

compressor to cool.

All maintenance and repair
operations not listed must be
performed by Trained Service
Technician.

Check
Valve

Nut

Outlet Tube

Advertising