Conair 100 User Manual

Page 45

Advertising
background image

Once power is turned on, this screen is dis-
played for 5 sec. while the control does
some self-checking.

Once power is turned on and screen 1 is
displayed for 5 sec., this screen is dis-
played for another 3 sec. It shows the
dryer model number for which the control
is configured.

After the model number is displayed, this
screen flashes for 1 sec. and displays the
control board software version.

After the control versions is shown, the
screen flashes again for 1 sec. and displays
the display board software version.

This is the DEFAULT screen. It shows the
process air temperature setpoint and actual
temperature measured at the inlet to the
drying hopper. The + / - buttons can be
used to change the setpoint. Holding the +
/ - buttons in will cause the number to
ramp up faster the longer the button is
held. The display will return to the default
screen from anyplace in the menu structure
if nothing is done after 10 min.

Indicates configuration as a central dryer.

Shows the regeneration air setpoint and
actual temperature. The setpoint can not be
changed from this screen; it is shown only
as a reference.

4

Opera

tion

O p e r a t i o n l

4 - 5

S c r e e n

SCREEN 1

SCREEN 2

SCREEN 3

SCREEN 4

SCREEN 5 (Default Screen)

SCREEN 5 (Default Screen)

SCREEN 6

Pr

F u n c t i o n

C o n t r o l F u n c t i o n D e s c r i p t i o n s

up

d

25

v00

09.5

C

v00

01.0

d

250

250

1

425

425

2

CNT

DRY

1

Central