PS Engineering

PCD7100 Series Audio Selector Panel and Intercom System

Installation and Operator’s Manual

200-971-0006

Appendix C

Rev. 8, Jan. 2015

7.2

PCD7100 w/out Intercom (11952, 11953, 11954, 11958)

22

1. All audio wiring must be MIL 22750 or 27500
24 AWG minumum..
2. Power and Ground #18AWG Mil-Spec Tefzel minimum.
Lighting #22 AWG minum.
3. Use 2A pull-type cicruit breaker.
4. Optional Alert Messages for units with
internally stored AWS messages.
Apply a ground to activate the specific message.
Close acknowledge switch to cancel.
5. Unswitched audio is summed
and presented to AWS output.
6. While the output of this device is designed
to work the majority of intercoms and
audio panels, PS Engineering can not
guarantee satisfactory results for all devices.

PCD7100-P J1 CONNECTOR

Notes:

C
3
6

21

4

5
9
7
10
8
11

1

A

Note 4

Z

15
S
14
R
13
P
12
N

Unswitched Audio Input 1 Hi
Unswitched Audio Input Lo
Unswitched Audio Input 2 Hi
Unswitched Audio Input Lo
Unswitched Audio Input 3 Hi
Unswitched Audio Input Lo
Unswitched Audio Input 4 Hi
Unswitched Audio Input Lo

Note 5