6trouble shooting – Cecilware ESP1 User Manual

Page 11

Advertising
background image

6

Trouble Shooting

Wait at least 3 seconds to restart the automatic espresso machine after turning it off to ensure
previous data stored in machine memory is erased. Turning the machine on too quickly may
cause the machine to function improperly.

11

Indication

Status

Possible Cause

Corrective
Actions

L

After two minutes of
water input, indicator
still does not show a
rise in machine water
level. It will take more
than two minutes to
replenish water when
the machine is used
for the first time.

1. Water level indicator not

functioning properly.

2. Water intake solenoid is

out of order. Input water
flow has been
interrupted.

1. Make sure that the water

input switch is ON and
that water is flowing into
the machine.

2. Turn off the machine.

Restart after 3 seconds.

3. Notify local dealer.

E

1. No water output from

the brewer.

2. Machine does not

reach preset
parameters.

1. Coffee grounds are too

fine.

2. No water input
3. Water intake solenoid is

out of order.

1. Adjust coffee ground

fineness.

2. Ensure water input is

normal.

3. Notify local dealer.

.

Boiler is in automatic
water input mode.

Boiler water level is too
low, automatic water
input system is working.

Indication of an action for
reference.

A or B

IC board does not
function properly.

Software or hardware
error.

1. Turn machine off.Restart

after 3 seconds.

2. Notify local dealer.

Advertising