CODE 142 - Vertical Louvers (Same as Option CD1) - UDAP/UDAS/UDBP/UDBS

Airflow directed

to the left;

springs are

on the top.

Airflow directed

to the right;

springs are on

the bottom.

Install and adjust vertical louvers to achieve desired airflow pattern.

CODE 140 - High Altitude Pressure Switch Kit - Above 6000 ft/1830M Elevation

(Same as Option DJ20, DJ21) - Models UDAP, UDAS, UDBP, UDBS as listed
See pressure switch locations in illustrations on pages 4 and 5.

Accessories/Options

CODE 141 - Vent Cap - Models UDAP and UDBP

(Same as Option CC1)

Code Description

30 45 60 75

100

125 150 175 200 225 250 300 350 400

140A Vent Cap for standard

UDAP and UDBP

111848, 4”

111849, 5”

111850, 6”

140B

Vent Cap for UDAP-CV

(Model UDAP with Option

AV6 for common venting)

111848, 4” 111849,

5”

--

--

--

--

--

--

--

--

--

Option DJ20 for

Model UDAP

installed as a

standard Power

Vented Fan-Type

Unit Heater

Model UDAP

30

45

60

75

100

125

150 175 200 225 250 300

350 & 400

before 7/23/09 after 7/23/09

Pkg P/N

197117

197118

197117

201162

201163

201162

High Altitude Switch P/N

197031

197032

197031

201160

201161

201160

Negative Pressure OFF

Setpoint “w.c.

0.35

0.45

0.35

1.0

1.30

1.0

Label color

Purple

Pink

Purple

Brown

White

Brown

Option DJ21

applies only to

Model UDAP-CV

with Option AV6

for Common

Venting

Model UDAP-CV

30

45

60

75

100

Pkg P/N

197119 197118

197120

197121

High Altitude Switch P/N

197029 197032

196362

196388

Negative Pressure OFF

Setpoint “w.c.

0.60

0.45

0.55

0.50

Label color

Lt Blue

Pink

White

Orange

Option DJ20 for

Model UDAS

Separated

Combustion Fan-

Type Unit Heater

Model UDAS

30

45

60

75

100

125

150 175 200 225 250 300

350 & 400

before 7/23/09 after 7/23/09

Pkg P/N

197119

197121 197205 197117

201162

201163

201162

High Altitude Switch P/N

197029

196388 197030 197031

201160

201161

201160

Differential Pressure OFF

Setpoint “w.c.

0.60

0.50

0.40

0.35

1.0

1.30

1.0

Label color

Lt. Blue

Orange Green

Purple

Brown

White

Brown

Option DJ20 for

Model UDBP

Power Vented

Blower-Type High

Static Unit Heater

Model UDBP

30

45

60

75

100

125

150 175 200 225 250 300

350 & 400

before 7/23/09 after 7/23/09

Pkg P/N

197117

197118

197117

201162

201163

201162

High Altitude Switch P/N

197031

197032

197031

201160

201161

201160

Negative Pressure OFF

Setpoint “w.c.

0.35

0.45

0.35

1.0

1.30

1.0

Label color

Purple

Pink

Purple

Brown

White

Brown

Option DJ20 for

Model UDBS

Separated

Combustion

Blower-Type High

Static Unit Heater

Model UDBP

30

45

60

75

100

125

150 175 200 225 250 300

350 & 400

before 7/23/09 after 7/23/09

Pkg P/N

197117 197118 202103 197118 197117 197205 197117

201162

201163

201162

High Altitude Switch P/N

197031 197032 196362 197032 197031 197030 197031

201160

201161

201160

Differential Pressure OFF

Setpoint “w.c.

0.35

0.45

0.55

0.45

0.35

0.40

0.35

1.0

1.30

1.0

Label color

Purple

Pink

White

Pink

Purple

Green

Purple

Brown

White

Brown

Size

30, 45

60, 75

100, 125 150, 175,

200

225, 250 300, 350,

400

Option Pkg P/N

197097

197098

197099

201199

201200

201201

Components
Louver Frame Top and

Bottom

(2)

197056

(2)

197189

(2)

197190

Louver Frame Sides

(2)

197057 (2)197058 (2)197059 (2)197186 (2)197187 (2)197188

Screws

(20)

195638, #8-18 x 3/8” long, AB point, slotted indented serrated hex

washer head

Louvers

(5)

196232 (5)196231 (5)196233 (8)196572 (8)196573 (8)195315

Compression Springs (5)

195046 (5)195046 (5)195046 (8)195046 (8)195046 (8)195046