Enter motor capacitor 7, Cirucit breaker 7, Co2 sensor 7, 9 – Reznor MAPSIV RECC Parts Manuals User Manual

Page 7: Contactor 7, 10, 36, Aridigm) 7, Iew) 7, Convenience outlet 7, 9, Digital controller 7, 21, 22, Dirty filter sensor 7, Air sensor 7, 9

Advertising
background image

Form P-MAPS III&IV, PN 262958R5, Page 7

Electrical Components - High Voltage Panel or a Heat Section Control Panel

Code Description

P/N

1A Phase Loss/Voltage Monitor (Opt PL4)

208/230/460V (AK5/6/7) -

176826; 575V (AK8) - 258881

1B Socket for Code 1A Monitors

194168

2

Distribution Block

207641, 115A; 222673, 250A; 223495, 310A

3

Transformers

11279, .25 kva (Fuse 261596, 5 amp time delay), Cutler Hammer S20N11S26

113556, .25 kva (Fuse 261696, 5 amp time delay), Sola-HD HS10B250

11100, 0.5kva, 480-230/120 (Fuse 201803, 3 amp), Cutler Hammer S20N11S51

202056, 0.5kva , 575-240/120 (Fuse 201803, 3 amp), Cutler Hammer S57N11S51N

16065, 1.0 kva (Fuse 90335, 5 amp), Cutler Hammer S20N11S01

209575, 1.0 kva (Fuse 90335, 5 amp), Cutler Hammer S60G11S01N

197085, 1.5kva, 480-230/120 (Fuse 115160, 8 amp), Cutler Hammer S20N11S16N

260918, 1.5kva, 600-240/120 (Fuse 115160, 8 amp), Cutler Hammer S60G11S16N

208989, 75va, 120/208/240/480-24V, includes circuit breaker, Functional Devices TR75VA005

223462, 1kva, 208-240/120V (D Cabinet with AG70 and AK5), Cutler Hammer S29N11S01

258912, 75va, 460/575-24V, Hartland Controls HCT-130J2K02199

11217, .75 kva, 240/480-120/240V, Cutler Hammer S20N11S76

4

Fuse for Transformer (Fuse Holder,

P/N 60241)

3amp,

201803; 5amp, 90335; 8amp, 115160; 10amp, 254953; 1.5amp w/time delay, 261956

Fuse for Controller Transformer

Cabinet D - 8 amp,

201773

5

Contactor

(

NOTE: For blower motor contactor,

see

Code 71 on page 10.)

for Condenser Fan

216386 (replaces 119625), 24v coil, 25A

for Compressors

216386 (replaces 119625), 24v coil, 25A

216387 (replaces 223021), 40 amp, 24v coil

216388 (replaces 208375), 50 amp, 24v coil

222674, 75 amp, 24v coil

Cabinet D w/2 Gas Heat Sctns

119626, 120v coil

6

Digital Controller - MAPS® IV w/digital scroll compressors

266067

7

Grounding Lug

179196

8

Variable Resistor (MOV) on Code 6 Digital Controller

(2)

255303 - for MAPS

®

IV Units with AK7 or AK8 and Reheat Option AUR1

Electrical Components - Low Voltage Panel or a Heat Section Control Panel

10 Unit-mounted Digital Controller Display (BacView)

222189 (Bracket P/N 256823)

11 IQ Digital Controller with Programmed Software

P/N 257604 - Replacement requires specific Model and Serial No. of the MAPS® system. Contact

your local Distributor with this information (found on the system rating plate.)

12 Control Expansion Board (BHB6)

222188

13 Plug-in Card with LON Software (BHB5) Assembly

234823

14 Air Proving Switch

234712

15 Relays

222482

211411 (Base, P/N 211415)

16 Interface Board (component of Option AUR1)

222769

17 Power Supply (component of Option BE16)

256654

18 Combustion Air Proving Switch (Gas Heat)

For P/N’s, see Table, page 8.

19A Sequencer (Gas Heat)

222755 - used on D Cabinet w/2 heat sections; JHUP300; & JHUP250

19B Sequencer (Electric Heat)

259224 - 8 stage; 222755 - 4 stage

20 Venter Motor Capacitor (Gas Heat)

See Table on page 8 for P/N by Heat Section.

21

Gas Heat Control Board (Varidigm Module)

*

Contact the factory for replacement ignition controller on

Cabinet D units w/Serial No. Ignition Codes 86-93 (See pg 2).

258319 - Cabinets A & B

CODE 22 - See page 8 for P/N’s of ID plugs unique to each heat

section - All A, B, and C Cabinets and D Cabinets mfgd beginning

8/11 (or earlier as specials).

257246 - Cabinet C

*

Cabinet D -

257246

23 DSI Board (single-stage heat section - D Cabinet only)

195573 (Replacement fuse for board, P/N 201685)

24 Time Delay Relay

221388 - (D Cabinet w/2 heat sections)

25 ECO Limit Device

82414 - (D Cabinet w/2 heat sections)

26 Thermal Cirucit Breaker - D Cabinet w/gas heat

262374

27 PAM Relay

222482

28 Wiring Harness

Cabinets A&B -

28A, 258956, and 28B, 257780; Cabinet C - 256661; Cabinet D - 223103

Various Sensors for Monitoring and Reporting to the IQ Digital Controller (Code 11) - Depending on the application, sensors may be standard or part

of optional controls (Opt BE__), controls for variable frequency drive (Opt VFC__), or damper controls (Opt GF__).

30 Discharge Air Sensor & Box, 8” probe

222753 (in the discharge ductwork)

31 Dry Bulb Temperature Sensor (in Opts GF9, BE9, BE10)

223111

32 Space Temperature Sensor (Option CL77)

222756

33 Return Air Temperature Sensor & Box, 8” probe

222753 (in the return air inlet)

34 Return Air Humidity Sensor (in Opts GF8 & BE14)

234907 (in the return air inlet)

35 Outside Air Humidity Sensor

222754 (in the outside air inlet)

36 Building CO2 Sensor (in Opts VFC5, GF&, & BE15)

234820

37 Photoelectric Smoke Detector (in SA1 & BE17)

159553 (SA1 includes sampling tube, P/N 259069)

38 Photohelic Dirty Filter Sensor (pressure gauge) (in BE16)

255784 - in the control compartment (see page 5 or 6)

39 Wall Humidity Sensor (Option DT7)

234822

40 Duct Static Pressure (in Option VFC3 & BE11)

Transducer,

P/N 234818; Sensor Port, P/N 234821

41 Building Static Pressure (in Option VFC4, GF5, & BE12)

Transducer, P/N

234819 (installed in the building)

42 Dirty Filter Pressure Switch (in Option BE18)

105507 (measures pressure drop)

Other Electrical Components

50 Convenience Outlet (BC2) - requires power supply

Box, P/N

17782; Receptacle, P/N 96912; Cover, P/N 209010

51 Ductstat (Return or Discharge) or Firestat (in Opt BD5)

42782

52 Remote Display for Digital Controller (Option RB3)

234835 (Includes Display, P/N 222189, & Power Supply, P/N 256654)

53 Non-fusible Disconnect Switch (in Option BA6)

See Table on page 9

54 Disconnect Switch (Option CP)

See Table on page 9.

55 Hand Held Display for Digital Controller (Option RB4)

258452

Electrical Components - Replacement P/N’s

For Location - Cabinet A, B, or C, see page 5; Cabinet D, see page 6. For an Illustration of most parts, see pages 8-10.