Heat shields 9, Gas pressure switch 9, Pressure switch 9 – Reznor HRPD Parts Manuals User Manual

Page 9: Emperature control 9, Ent limiter 9

Advertising
background image

Form P-RG/RP/RBL, P/N 263984R4, Page 9

Carryover

Regulator

Modulating

Valve

Single-Stage

Gas Valve

Primary Gas Flow Pressure Switch,

White Label, 1.1” w.c., P/N 174809

For AG 39, 40, 41, 42 with a solenoid actuator (mfgd

before 11/03), Backup Gas Flow Pressure Switch, Yellow

Label 1.4” w.c., P/N 175985

For AG 39, 40, 41, 42 with a gear motor (mfgd beginning

11/03), there are two gas flow pressure switches with the

white label, 1.1” w.c., P/N 174809

Vent Limiter,

Maxitrol A1209,

P/N 123481

Codes 8, 9, 10 - Gas Pressure Switches

Bracket,

P/N

100261

Code 10 - High Gas

Pressure Switch,

P/N 93850

Manual Reset, Settings - 125%

of normal manifold gas pressure

as stated on the unit rating plate

Codes 8 & 9 - Low Gas

Pressure Switch, P/N 93849

(Range 1-6" w.c.); P/N

149176 (Range 6-24" w.c.)

Automatic Reset, Settings - 50%

of minimum inlet gas pressure

as stated on the unit rating plate

Code 12 - Time Delay

Relay , P/N 259780

Code 13A -

Limit Control,

P/N 50417,

opens 125°F;

closes 105°F

Code 13B - Limit

Control Shield,

P/N 12229

Used with Code

13A on Models

RG and RGB

For units manufactured prior to

12/04, the temperature activated fan

control is no longer available. Order

Replacement Kit,

P/N 209184.

Code 15 - Time

Delay Relay,

T & B Agastat

TM1ULA,

P/N 89661

Used in the

freezestat circuit

.

Codes 16 & 17; 19

& 20; and 40 & 41

Terminal Block,

P/N 144972

Terminal

Block

Adapter,

P/N

144973

Code 18 - Heat Shields (on

units mfgd prior to 12/04)

For U.S.

Unit,

P/N

10188

For

Canadian

Unit,

P/N 63818

Code 21 - Freezestat

Relay, P/N 211411 and

P/N 211415

Code 22 - Dirty

Filter Pressure

Switch, Tridelta

AP4434,

P/N 105507

Field adjustable;

range .17 to 5.0" w.c.

plus or minus .05" w.c

.

Code 25 - Fuse

and Fuseholder

Fuse Holder,

P/N 60241

Fuses:

2-1/2 Amp, P/N 201773,

Bussman FNM8

5 Amp, P/N 201780,

Bussman FNM3

8 Amp, P/N 204803,

Bussman MDL3

Code 26 -

Convenience Outlet

Receptacle,

P/N 96912

Code 27A - Motor

Contactor, 24V Coil,

P/N 216386 (replaces

P/N's 93661 and 119625)

For blower motor

starters, see page 27-30.

Code 11 - Manifold and Control with Gas Pressure Switches used

in Modulating Gas Control Options AG39, AG40, AG41, AG42

NOTE: Carryover regulator parts

are on page 17. See Parts Form

P-VALVES for gas valves.

Used on RG, RGB, RP, RPB

Series units; for "BL" packaged

systems, see page 10.

NOTE: Limit Control for RP/

HRPD with Option BU12 is

P/N

196571, 140°F, red/white label

Code 28 - Temperature

Control, J/C #A19ABC-24,

-30 to 100°F, used in Gas

Control Option AG41 and

AG42 on Models RPBL and

HRPD, P/N 197204

Code 14 - SPST Time Delay

Relay (for fan/blower control on

units mfgd beginning 12/04), P/N

209164, Thermodisc I2S20-305131

To replace time delay

relay (P/N 46233 or

259518) used on product

manufactured prior to

2/2010, order replace-

ment kit,

P/N 259521.

For units manufactured

prior to 9/2011, order

a replacement kit,

P/N

263527, to replace

relay.