Form P-RIH/VR, PN 272513, Page 2

Size Conversion Label - Model VR - When servicing a heater with a rating plate reading Model VR75, VR125, or

VR175,

always look for a Size Conversion label.

• Rating Plate reads Model VR75 AND Size Conversion Label reads VR100 - Service heater as a Model VR100.

• Rating Plate reads Model VR125 AND Size Conversion Label reads VR150 - Service heater as a Model VR150.

• Rating Plate reads Model VR175 AND Size Conversion Label reads VR200 - Service heater as a Model VR200.

Year

Jan

Feb

Mar

Apr

May

June

July

Aug

Sept

Oct

Nov

Dec

2002

BBA

BBB

BBC

BBD

BBE

BBF

BBG

BBH

BBI

BBJ

BBK

BBL

2003

BCA

BCB

BCC

BCD

BCE

BCF

BCG

BCH

BCI

BCJ

BCK

BCL

2004

BDA

BDB`

BDC

BDD

BDE

BDF

BDG

BDH

BDI

BDJ

BDK

BDL

2005

BEA

BEB

BEC

BED

BEE

BEF

BEG

BEH

BEI

BEJ

BEK

BEL

2006

BFA

BFB

BFC

BFD

BFE

BFF

BFG

BFH

BFI

BFJ

BFK

BFL

2007

BGA

BGB

BGC

BGD

BGE

BGF

BGG

BGH

BGI

BGJ

BGK

BGL

2008

BHA

BHB

BHC

BHD

BHE

BHF

BHG

BHH

BHI

BHJ

BHK

BHL

2009

BIA

BIB

BIC

BID

BIE

BIF

BIG

BIH

BII

BIJ

BIK

BIL

2010

BJA

BJB

BJC

BJD

BJE

BJF

BJG

BJH

BJI

BJJ

BJK

BJL

2011

BKA

BKB

BKC

BKD

BKE

BKF

BKG

BKH

BKI

BKJ

BKK

BKL

2012

BLA

BLB

BLC

BLD

BLE

BLF

BLG

BLH

BLI

BLJ

BLK

BLL

2013

BMA

BMB

BMC

BMD

BME

BMF

BMG

BMH

BMI

BMJ

BMK

BML

2014

BNA

BNB

BNC

BND

BNE

BNF

BNG

BNH

BNI

BNJ

BNK

BNL

2015

BOA

BOB

BOC

BOD

BOE

BOF

BOG

BOH

BOI

BOJ

BOK

BOL

IMPORTANT

This appliance has been converted at the time of installation to a model

Cet appareil a ete converti au moment de l’installation en un modele _____(100, 150, or 200) _____

by

with kit no.

per ________(name of service person or agency)_________

avec la kit n

o

__(Kit P/N)___

which accepts the responsibility that this conversion has been properly made.

ce qui accepte la responsabilite que cette conversion a ete correctement faite.
Orifice Size

Dimension de l’orifice

__(New Orifice Size)__Drill Foret

Normal input

Entrée Normale

__(100,000; 150,000; or 200,000)_BTU/HR

Minimum permissible gas supply pressure for purpose of input adjustment _(*)_in. w.c.

Pres. D’alim. Min. acceptable de gaz pour des fin de reglace de l’entrée

__(*)__ PO/COL D’eau

Rating Plate and

Serial No. (Model VR)

Rating Plate Key:

A = Model

B = ANSI Certification

C = CSA Certification

D = Mfg Date (month & year)

E = Supply Voltage

F = Type of Fuel (natural gas or

propane)

G = Burner Orifice Drill Size

H = Input (BTUH)

I = Manifold Pressure (“ w.c.)

J = Minimum Gas Supply

(inches w.c.)

K = Clearances to

Combustibles - Burner End

L = Clearance to Combustibles

- Heat Exchanger Bend

M = Clearance to Combustibles

- Below

N = Clearance to Combustibles

- Front/Rear, 0-30°

Reflector

O = Clearance to Combustibles

- Front/Rear, 31-45°

Reflector

P = Clearance to Combustibles

- Front/Rear, 0-30°

Reflector with Side Shield

CODES:

Serial No. Decoding

Example:

BJK 80 6A N 12345

1

2

3

4

5

First Element of the

Serial Number - Date of

Manufacture (Model VR)

REZNOR

®

MERCER, PA. USA 16137

MADE IN MEXICO

NRTL

INFRARED RADIANT TUBE HEATER

FOR INDUSTRIAL/COMMERCIAL USE ONLY

FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL

DWELLINGS CERTIFIED UNDER ANSI Z83.20b - [ B ] CSA 2.34b - [ C ]

LOW INTENSITY INFRARED HEATER

MODEL

[ A ]

SERIAL #

[ C ]

[ E ] VOLTS [ E ] PH [ E ] HZ MAXIMUM TOTAL INPUT [ E ] AMPS

TYPE OF GAS

[ F ]

FOR USE AT 0-2000 FEET, 0-610 METERS OF ALTITUDE

ORIFICE SIZE

[ G ] DRILL

NORMAL INPUT

[ H ] BTU/HR

NORMAL MANIFOLD PRESSURE [ I ] IN. W.C.

MIN PERMISSIBLE AS SUPPLY PRESSURE FOR

PURPOSE OF INPUT ADJUSTMENT

[ J ] IN. W.C.

CLEARANCE TO COMBUSTIBLE CONSTRUCTION: TOP - 12”*; FLUE

CONNECTION - 6”; BURNER END [ K ]; EXHAUST END - 24”; HEAT

EXCHANGER BEND (U OR L) [ L ]

*18” IF UNVENTED

REFLECTOR

MAX MOUNTING

ANGLE

BELOW

(FRONT/

REAR)

STANDARD REFLECTOR

0 TO 30 DEG

[ M ]

[ N ]

STANDARD REFLECTOR

31 TO 45 DEG

[ M ]

[ O ]

STANDARD REFLECTOR W/SIDE

SHIELDS (ONE SIDE ONLY)

0 TO 30 DEG

[ M ]

[ P ]

THIS UNIT CAN BE INSTALLED IN VARIABLE CONFIGURATIONS AS

SPECIFIED IN THE MANUFACTURER’S FORM T-VR-CNFG.

FOR STRUCTURES LISTED BELOW, USE APPLICABLE STANDARDS.

INSTALLATION OF THIS UNIT IN AIRCRAFT HANGARS IN CANADA

MUST BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE

ENFORCING AUTHORITIES.

IN PUBLIC GARAGES, IN ACCORDANCE WITH THE CAN/CGA-B149 (.1

OR .2) CODES IN CANADA.

AIRCRAFT HANGARS USE STANDARD ANSI/NFPA 409 IN THE USA

PARKING STRUCTURES USE STANDARD ANSI/NFPA 88A IN THE USA

REPAIR GARAGES USE STANDARD ANSI/NFPA 88B IN THE USA

FOR USE WITH TYPE L VENT

FOR INDOOR INSTALLATION ONLY

THIS UNIT IS FOR USE WITH NATURAL GAS AND PROPANE

A CONVERSION KIT AS SUPPLIED BY THE MANUFACTURER SHALL

BE USED TO CONVERT THE HEATER TO THE ALTERNATE FUEL.

REZNOR

®

MERCER, PA. USA 16137

FABRIQUÉ AU MEXIQUE

NRTL

INFRARED RADIANT TUBE HEATER

POUR USAGE INDUSTRIEL/COMMERCIAL SEUL

INSTALLATION ÀĹINTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS

UN LOGEMENT. CERTIFIED UNDER ANSI Z83.20b - [ B ] CSA 2.34b - [ C

] LOW INTENSITY INFRARED HEATER

MODELE

[ A ]

#DE SÉRIE

[ D ]

[ E ] VOLTS [ E ] PH [ E ] HZ CONSOMMATION TOTALE MAX. DE [ E ]

AMPS

TYPE DE GAZ

[ F ]

PRÉVU POUR 0-2000 PIEDS, 0-610 MÉTRES D’ALTITUDE

DIMENSION DE L’ORIFICE

[ G ] FORET

ENTRÉE NORMALE

[ H ] BTU/HEURE

PRESSION NORMALE DE

LA TUB

[ I ] PO/COL D’EAU

PRES. D’ALIM. MI. ACCEPTABLE DE GAZ PÓUR

DES FIN DE RÉGLACE DE L’ENTREE

[ J ] PO/COL

D’EAU

DÉGAGEMENT ENTREE LES CONSTRUCTIONS COMBUSTIBLES: EN

HAUT - *12 PO, RACCORD DE TUYAUX - 6 PO, CÓTÉ BRULEUR - [ K ];

CÓTÉ EVACUATION - 24 PO, COUDE D’ÉCHANGEUR (U OR L) [ L ]

*18 PO SI NON VENTILÉ

RÉFLECTEUR

ANGLE DE MONTAGE

MAX.

DESSOUS

(AVANT/

ARRIÉRE)

RÉFLECTEUR STANDARD

0 Â 30 DEG

[ M ]

[ N ]

RÉFLECTEUR STANDARD

31 Â 45 DEG

[ M ]

[ O ]

RÉFLECTEUR STANDARD

AVEC CÓTÉ ÉCRANS (UN CÓTÉ

SEULEMENT)

0 Â 30 DEG

[ M ]

[ P ]

CET APPAREIL PEUT ÊTRE INSTALLÉ SELON DES CONFIGURATION

VARIABLES COMME IL EST STIPULÉ DANS LE FORMULAIRE T-VR-

CNFG DU FABRICANT

L’INSTALLATION DE UNITE DANS CES GARAGES D’AVIONS DOIT SE

CONFORMER AUX CONDITIONS DES AUTHORITÉS CHARGÉES DE

FAIRE.

APPLIQUER LA LOI. L’INSTALLATION DANS DES GARAGES PUBLICS

DOIT SE CONFORMER AU CODE CAN/CGA-B149 (.1 OU.2).

S’UTILISE AVEC UN ÊVENT DE TYPE L.

FOR INDOOR INSTALLATION ONLY

CET APPAREIL POUR UTILISATION AVEC LE GAZ NATURAL ET LE

PROPANE.

UNE TROUSSE DE CONVERSION FOURNIE PAR LE FABRICANT UNE

TROUSSE DE CONVERSION FOURNIE PAR LE FABRICANT

Example of a Size

Conversion Label

* Minimum supply pressure

is 5” w.c. for natural gas for

Sizes 50-150; 6” w.c. for

natural gas for Sizes 175-

200; or 10” w.c. for propane

gas for all sizes.

1 = Date of manufacture (see chart below)

2 = Type of ignition

3 = Type of valve

4 = Type of gas (N= Natural; L= Propane)

5 = Consecutive number (for identification purposes only)