Figure 3-4

Unit Mounting Dimensions Without Tray

3.4.2.2 Hard Mounting without Tray

The STX 165R can be hard mounted to the aircraft using the slotted fl anges on the unit using either
number 6 or number 8 mounting screws. It can be mounted in either axis. When mounted on the
narrow edge two screws are used to fasten the unit. When on the wide edge, either three or four
mounting screws are required. When mounting the unit, ensure that enough clearance is allowed for
the mating connectors.

12

3.5

Static Port Connection

The STX 165 has a built-in altitude encoder that requires connection to the aircraft static port. The
static port connection is on the back of the STX 165. To ensure a leak proof fi t, it is recommended
to use tubing with an Inside Diameter of .125” and secure it with a hose clap or ty-wrap. Upon
completion of the STX 165 installation a leak test of the static line is to be performed per

FAR Part 43 Appendix E.